Chapter 5: Error Messages and Troubleshooting
37
No network interfaces
The system cannot detect any network
interfaces.
1.
Turn off the system and verify that
all NICs are seated properly in the
appropriate expansion slots.
2.
Run diagnostics to check the
onboard Ethernet port.
If the problem persists, contact
Network Appliance Customer
Support.
Dirty shutdown in
degraded mode
The file system is inconsistent
because you did not shut down the
system cleanly when it was in
degraded mode—C2100 only.
Contact Network Appliance Customer
Support for instructions about
repairing the file system.
No NVRAM present
The system cannot detect the
NVRAM adapter—C2100 only.
Make sure that the NVRAM adapter is
securely installed in riser and is
plugged in properly.
Replace NVRAM
batteries
The NVRAM battery is low. The
system shuts down immediately—
C2100 only.
Recharge the battery.
NVRAM #n downrev
n
—The serial number of the NVRAM
adapter. The NVRAM adapter is an
early revision that cannot be used with
the system—C2100 only.
Check the console for information
about which revision of the NVRAM
adapter is required. Replace the
NVRAM adapter.
NVRAM test failed
An error occurred while the system
tested the NVRAM—C2100 only.
Contact Network Appliance Customer
Support if this message appears.
Unsupported NVRAM
size %dMB
%d
—The amount of memory on the
NVRAM adapter. The specified size is
not supported—C2100 only.
Verify that the system has 64 MB of
NVRAM.
Boot error message
Explanation
Corrective action