background image

 

 

Function Key 

Press and hold for 5 seconds 

Restore to factory setting / Turn off 

The green indicator flashes for 20 times: success 

The green indicator remains off: fail 

Press once   

The device is in the network: the green indicator flashes once and the device sends a data 

report 

The device is not in the network: green indicator remains off 

Low Voltage Threshold 

Low Voltage Threshold 

10.5 V 

Restore to Factory Setting 

Instruction 

RA0708_R72608_RA0708Y has a network information memory function when power-down.   

This function is turned off by default, that is, it will be re-joined every time it is powered on.   

This function can be turned on by the ResumeNetOnOff command.   

At this time, each time the power is rewritten, the last network joining information will be 

recorded (including saving the network address information assigned to it, etc., if you want to 

join a new network, you need to perform a factory resetting operation first.)     

It will not be re-joined the previous network. 

 

Operation 

1.

 

Press and hold the button for 5 seconds and release (the binding button is released when the 

LED flashes), and the   

LED flashes for 20 times. 

2. The device will automatically restart to re-joining. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for R72608

Page 1: ...is document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in...

Page 2: ...duction 2 2 Appearance 2 3 Main Features 3 4 Set up Instruction 3 5 Data Report 5 6 Installation 8 6 1 RA0708 8 6 2 R72608 8 6 3 RA0708Y 9 6 4 PH Sensor Use 9 6 5 PH Sensor Maintenance 11 7 Important...

Page 3: ...ectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation eq...

Page 4: ...times Power off Remove power Note 1 Engineering test modes require the burning engineering test software 2 On off interval is suggested to be about 10 seconds to avoid the interference of capacitor i...

Page 5: ...tion when power down This function is turned off by default that is it will be re joined every time it is powered on This function can be turned on by the ResumeNetOnOff command At this time each time...

Page 6: ...8Y Invalid configuration 4 Report cycle will be based on ReportMaxTime period when sending data packet beginning to the end of the first data as a period 5 Data packet temperature voltage and PH value...

Page 7: ...xTime MaxTime Sleeping MinTime Sleeping MinTime Note MaxTime MinTime Data will only be report according to MaxTime MinTime duration regardless BatteryVoltageChange value Description Device Cmd ID Devi...

Page 8: ...recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matte...

Page 9: ...opriate size cylinder on the main bracket of the solar panel and install the gasket in sequence Lock nut till the solar panel is stable and does not shake 3 Adjust the angle of the solar panel After t...

Page 10: ...2 Loosen the M5 nut at the bottom of the RA0708Y matte and take the matte together with the screw 3 Insert the power DC plug from the center through hole of the RA0708Y bottom cover and insert it int...

Page 11: ...10 15...

Page 12: ...maintained in the above manner the sensor has failed Please replace the sensor 7 Important Maintenance Instruction Your device is a product of superior design and craftsmanship and should be used wit...

Reviews: