6
Report Configuration Example:
(1) Configure RA0708 device parameters MinTime = 30s, MaxTime = 120s (120>30*1+10)
Downlink: 0105001E00780000000000
Device returns:
8105000000000000000000 (configuration is successful)
8105010000000000000000 (configuration failed)
(2) Read RA0708 device parameters
Downlink: 0205000000000000000000
Device returns:
8205001E00780000000000 (device current parameter)
Example for MinTime/MaxTime logic:
Example#1
based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
MaxTime MaxTime
Sleeping(MinTime)
Sleeping(MinTime)
Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BatteryVoltageChange value.
Description
Device
Cmd
ID
Device
Type
NetvoxPayLoadData
Config
ReportReq
RA07 Series
R726 Series
R727 Series
0x01
0x05
0x09
0x0D
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
Reserved
(5Bytes,Fixed 0x00)
Config
ReportRsp
0x81
Status
(0x00_success)
Reserved
(8Bytes,Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved
(9Bytes,Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
Reserved
(5Bytes,Fixed 0x00)
Wake up and collects data
REPORTS 3.6V
Wakes up and collects data
REPORTS 3.6V
Wakes up and collects data
REPORTS 3.6V