background image

 

 

 

Example#2

 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.

 

 

                                                                       

 

MaxTime

 

 

 

 

 

Sleeping(MinTime)             

   

  sleeping                          sleeping   

   

                sleeping 

 

 

0H

                                  15

th

 M                              30

th

 M                        45

th

 M                             

1H

                                                                                                2H 

                   

 

 

 

 

 
 

Example#3 

based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. 

 

 

 

                                                                                                                                                                                                             

MaxTime 

 

 

 

 

       

 

sleeping                          sleeping

 

                ...

 

 

 

0H

                          15

th

 M                       

30

th

 M 

                    45

th

 M                            1H   

1H 10

th

 M

          1H 25

th

 M                      1H 40

th

 M                1H 55

th

 M             

2H 10

th

 M

                                       

 

 

 

 

 

 

 

Notes : 

1)

 

The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it does not collect 

data. 

2)

 

The data collected is compared with the last data reported. If the data variation is greater than the ReportableChange value, the 

device reports according to MinTime interval. If the data variation is not greater than the last data reported, the device reports 

according to MaxTime interval. 

3)

 

We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is too low, the device wakes up 

frequently and the battery will be drained soon. 

4)

 

Whenever the device sends a report, no matter resulting from data variation, button pushed or MaxTime interval, another cycle 

of MinTime/MaxTime calculation is started. 

 

 

 

Wakes up and 

collects data 

3.6V   

Does not report   

Wakes up and 

collects data 

3.6V 

Does not report 

 

 

Wakes up and 

collects data 

3.6V 

Does not report   

 

 

Wakes up and 

collects data 

REPORTS 3.6V 

 

Wakes up and 

collects data 

REPORT 3.6V 

Wakes up and 

collects data 

REPORTS 3.6V 

 

Wakes up and collects data 

3.5V |3.5-3.6|=0.1 

REPORTS 3.5V 

Wakes up and 

collects data 

3.5V   

Does not report   

Wakes up and 

collects data 

3.5V   

Does not report   

Wakes up and 

collects data   

3.5V   

Does not report   

Wakes up and 

collects data 3.5V 

Does not report 

 

 

 

Wakes up and 

collects data     

3.5V   

Does not report   

 

Wakes up and 

collects data 

REPORTS 3.5V 

Wakes up and 

collects data 

3.6V 

  Does not report   

Users push the button, 

REPORTS 3.5V. 

Recalculate MaxTime. 

 

 

Summary of Contents for R72608

Page 1: ...is document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in...

Page 2: ...duction 2 2 Appearance 2 3 Main Features 3 4 Set up Instruction 3 5 Data Report 5 6 Installation 8 6 1 RA0708 8 6 2 R72608 8 6 3 RA0708Y 9 6 4 PH Sensor Use 9 6 5 PH Sensor Maintenance 11 7 Important...

Page 3: ...ectrum modulation method greatly increases to expand the communication distance Widely used in long distance low data wireless communications For example automatic meter reading building automation eq...

Page 4: ...times Power off Remove power Note 1 Engineering test modes require the burning engineering test software 2 On off interval is suggested to be about 10 seconds to avoid the interference of capacitor i...

Page 5: ...tion when power down This function is turned off by default that is it will be re joined every time it is powered on This function can be turned on by the ResumeNetOnOff command At this time each time...

Page 6: ...8Y Invalid configuration 4 Report cycle will be based on ReportMaxTime period when sending data packet beginning to the end of the first data as a period 5 Data packet temperature voltage and PH value...

Page 7: ...xTime MaxTime Sleeping MinTime Sleeping MinTime Note MaxTime MinTime Data will only be report according to MaxTime MinTime duration regardless BatteryVoltageChange value Description Device Cmd ID Devi...

Page 8: ...recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matte...

Page 9: ...opriate size cylinder on the main bracket of the solar panel and install the gasket in sequence Lock nut till the solar panel is stable and does not shake 3 Adjust the angle of the solar panel After t...

Page 10: ...2 Loosen the M5 nut at the bottom of the RA0708Y matte and take the matte together with the screw 3 Insert the power DC plug from the center through hole of the RA0708Y bottom cover and insert it int...

Page 11: ...10 15...

Page 12: ...maintained in the above manner the sensor has failed Please replace the sensor 7 Important Maintenance Instruction Your device is a product of superior design and craftsmanship and should be used wit...