background image

 

 

LKG 610 

  

 

 

 

 

 

Netech Corporation 

110 Toledo St, Farmingdale, NY 11735,  

 

http://www.NetechCorp.us

 

http://www.PressureMeter.com

 

 

 

 

CAUTION

 

 

The 

CAUTION

 sign denotes a hazard. It calls attention to a procedure, practice or 

the like, which, if not correctly performed or adhered to, could result in damage to or 

destruction of part or the entire instrument. Do not precede beyond a 

CAUTION

 

sign until the indicated conditions are fully understood and met. 

 

 

The symbol to the left is the operator’s manual symbol. When you see this 

symbol on the instrument, refer to the operator’s manual. 

 

Returns and Credits  

 

Please note that only serialized products and their accessory items (i.e., products and 

items bearing a distinct serial number tag) are eligible for partial refund and/or credit. 

Non-serialized parts and accessory items (e.g., cables, carrying cases, auxiliary 

modules, etc.) are not eligible for return or refund. Only products returned within 60 days 

from the date of original purchase are eligible for refund/credit.  

 

In order to receive a partial refund/credit of a product purchase price on a serialized 

product, the product must not have been damaged by the customer or by the carrier 

chosen by the customer to return the goods, and the product must be returned complete 

(meaning with all manuals, cables, accessories, etc.) and in “as new” and resalable 

condition.  

 

Products not returned within 60 days of purchase, or products, which are not in “as 

new”, and resalable condition, are not eligible for credit return and will be returned to the 

customer. The Return Procedure (see below) must be followed to assure prompt refund 

/ credit. 

 

Restocking Charges 

Products returned within 30 days of original purchase are subject to a minimum 

restocking fee of 15 %.  Products returned in excess of 30 days after purchase, but prior 

to 60 days, are subject to a minimum restocking fee of 20 %. Additional charges for 

damage and / or missing parts and accessories will be applied to all returns. 

 

Summary of Contents for LKG 610

Page 1: ...LKG 610 Netech Corporation 110 Toledo St Farmingdale NY 11735 http www NetechCorp us http www PressureMeter com LKG 610 Electrical Safety Analyzer With 10 ECG Connectors INSTRUCTION MANUAL...

Page 2: ...pair and Recalibration 6 Models and Part Numbers 7 General Overview Introduction 8 Key Features 8 Specifications 9 Instrument Familiarity 10 Controls Indicators 11 Preparation for use 12 Operating Ins...

Page 3: ...otice and without incurring any obligation Netech guarantees availability of service parts for 5 years after the manufacture of the unit is discontinued The warranty is void if you elect to have the u...

Page 4: ...st procedures are found to meet those specifications when it was shipped from the factory Calibration LKG 610 is calibrated using standards traceable to National Institute of Standards and Technology...

Page 5: ...return or refund Only products returned within 60 days from the date of original purchase are eligible for refund credit In order to receive a partial refund credit of a product purchase price on a s...

Page 6: ...aging or handling Use the original carton and packaging material for shipment Returns for Refund Credit A Return Material Authorization RMA number must be obtained from our service or customer service...

Page 7: ...p www PressureMeter com Models and Part Numbers Part Number Description 535 110 10 Lead Electrical Safety Analyzer 110 V 535 220 10 Lead Electrical Safety Analyzer 220 V Standard Accessories Part Numb...

Page 8: ...ted and the unit of measure is indicated by an individual LED Either the AAMI ESI 1993 or the IEC 601 1 test load may be selected Resistance measurements are made using the included model 503 single c...

Page 9: ...SD DEVICE CURRENT 0 to 19 99 Amps Accuracy 2 Full Scale 1 LSD Line Voltage 1 to 300 Volts Accuracy 2 1 Volt TEST RECEPTACLE Hospital Grade 110 VAC 15 Amp or 220 VAC 10 Amp The rocker polarity switch s...

Page 10: ...User Manual LKG 610 10 Instrument Familiarity 2 15 1 14 12 13 11 10 9 3 4 5 6 7 8...

Page 11: ...nnection to the test receptacle 7 Polarity Switch A three position switch to select the normal and reverse polarity of the test receptacle The center position shuts the power off to the test receptacl...

Page 12: ...110 Volt devices only 2 PN 535 220 for 220 Volt devices only Before proceeding with any measurement become familiar with the measurements and the function selector switch CAUTION Make sure that the po...

Page 13: ...ice Current in Amps 3 Earth Leakage Current Measurement Press the EARTH LKG key See Figure 2 The Earth Leakage Ground Leakage Current is measured through the ground conductor of the Device Under Test...

Page 14: ...he Cord Resistance in milliohms Hammer pressure levels in excess of 20 PSI will cause damage t Figure 2 Block Diagram for Cord Resistance measurement and Case Leakage measurement external 5 Leads Leak...

Page 15: ...CAUTION During Isolation leakage measurements the LKG 610 introduces line voltage into the patient leads Even though it is current limited to 1milliAmp it is potentially lethal 7 Case Leakage Current...

Page 16: ...ASSIS When the CHS GND switch is momentarily pressed the connection will be open and the display will read zero A test lead other than the 503 may require adjustment with the zero adjustment control 3...

Page 17: ...akage current measurement the AAMI LOAD is connected in front of the INPUT AMPLIFIER and the voltage developed across it from the leakage current is measured Current Source and Amplifier Resistance is...

Page 18: ...first year warranty expires Netech will provide a second year warranty The warranty is void if the LKG 610 is serviced by anyone other than Netech or if the warranty seal is broken Calibration Servic...

Page 19: ...ssing of the service required To obtain a RMA number follow the link http www NetechCorp us and fill in the required information Email service netechcorp us or call 800 547 6557 US Canada Internationa...

Page 20: ...User Manual LKG 610 20 Appendix This section is intentionally left blank for future use...

Reviews: