Quality Assurance

 

 

Netech Corporation is ISO 9001-2000 Certified. This 
instrument was thoroughly tested and inspected 
according to Netech’s ISO 9001-2000 quality standards 
and test procedures, and was found to meet those 
specifications when it was shipped from the factory. 

 

Warranty

 

 

Netech warranties the LKG 601 against defects in 
materials and workmanship for one year from the date 
of original purchase. 

The standard warranty is 

extended for a second year if the instrument is 
returned to Netech for its recommended yearly 
recalibration.

 

 

During the warranty period, we will repair or, at our 
option, replace at no charge a product that proves to be 
defective, provided you return the product shipping 
prepaid to Netech Corporation. This warranty does not 
apply if the product has been damaged by accident or 
misuse, or as the result of service or modification by 
other than Netech Corporation, or if its serial number is 
defaced or removed. 

Summary of Contents for LKG 601

Page 1: ...INSTRUCTION MANUAL LKG 601 Electrical SafetyAnalyzer 110 Toledo Street Farmingdale NY 11735 USA http www Netech org 510 USER Manual Rev3 10 29 2007...

Page 2: ...anufacturer of advanced biomedical and industrial test instruments We are ISO 9001 2000 Certified and fully committed to a continuous improvement process Further we guarantee absolute satisfaction wit...

Page 3: ...hipped from the factory Warranty Netech warranties the LKG 601 against defects in materials and workmanship for one year from the date of original purchase The standard warranty is extended for a seco...

Page 4: ...d or calibrated by someone other than Netech The purchaser assumes all liability for any damages or bodily injury that may result from the use or misuse of the unit by the purchaser his employees agen...

Page 5: ...injury Do not proceed beyond a WARNING sign until the indicated conditions are fully understood and met CAUTION The CAUTION sign denotes a hazard It calls attention to a procedure practice or the lik...

Page 6: ...on for use 11 Operating Instructions 12 Maintenance 16 Theory of Operation 17 Specifications 19 Instructions for Return 21 LIST OF FIGURES Figure 1 Front view LKG 601 8 Figure 2 Block Diagram Cord Res...

Page 7: ...to be performed The user may select either the AAMI ESI 1993 or the IEC 601 1 test load to compensate for high frequency components in the measurement Accurate resistance measurements are made via a s...

Page 8: ...10 1 11 13 7 12 2 4 3 5 6 8 9 Power Cable Test Receptacle Figure 1 Front view of the LKG 601 8...

Page 9: ...tacle 5 POLARITY SWITCH A three position switch to select the normal and reverse polarity of the test receptacle The center position shuts the power off to the test receptacle 6 NEUTRAL SWITCH A switc...

Page 10: ...1 TEST JACKS A calibrated output is provided at the test jack for resistance and current functions This performs a self check of the LKG 601 12 ZERO ADJUSTMENT This recessed adjustment allows for the...

Page 11: ...h the measurements and the function selector switch During the initial setup the last digit of the LCD will change gradually due to the time constant of the RMS to DC converter The display will stabil...

Page 12: ...the Device Under Test into the test outlet Using the test lead provided connect the chassis of the Device Under Test to the Case Ground jack on the LKG 601 The display will indicate the Power Cord Res...

Page 13: ...other connection required To measure the Case Leakage of devices with plastic enclosures wrap aluminum foil around the case and connect the test lead to the foil The Case Leakage Current is measured...

Page 14: ...ay the Device Current in Amps CAUTION Do not attempt to open the unit There are no user serviceable parts inside Further the warranty will be void if the unit is opened by other than Netech trained pe...

Page 15: ...f necessary adjust the display to zero When the open ground switch is pressed down the connection will be open 4 Connect the Test Lead to the TEST JACK Move the selector switch to CORD RESISTANCE The...

Page 16: ...sistance functions This feature is useful to check the integrity of the unit When making a resistance measurement with a Test Cable other than the one supplied with the LKG 601 the user can zero the l...

Page 17: ...G 601 BLOCK DIAGRAM DESCRIPTION Test Load The input test load is user selectable to AAMI ESI 1993 or to IEC 601 RMS Converter and Amplifier The input amplifier buffers the input The RMS converter gene...

Page 18: ...with the input amplifier Test Receptacle This supplies power to the unit under test 110 VAC rated at 15 Amps 220 VAC The rocker polarity switch selects NORMAL OFF and REVERSES polarity in the test re...

Page 19: ...5 of reading 1 LSD 100 KHz to 1 MHz RESISTANCE 0 TO 1999 Milli Ohms Accuracy 1 of reading 1 LSD DEVICE CURRENT 0 to 19 99 Amps Accuracy 2 Full Scale 1 LSD TEST RECEPTACLE Hospital Grade 110 VAC 15 Amp...

Page 20: ...Operating range 59 to 950 F 15 to 400 C Storage Temperature 0 to 1220 F 20 to 600 C Relative Humidity 90 max at temperatures STANDARD ACCESSORIES Description Part Number User Manual 510 MANUAL Test C...

Page 21: ...hly inspected The delivering carrier s paper should be signed noting the apparent damage If the instrument is damaged beyond use a new order should be placed with NETECH while awaiting reimbursement f...

Page 22: ...Securely package your instrument in a strong box surrounded by at least two inches of suitable shock absorbing material 4 Include a copy of the purchase order or reference your purchase order on your...

Page 23: ...and TEST JACK Between 1 to 2 Select CORD RESISTANCE Display will read 1050 1100 Approximately This will include the total resistance of 1000 milliohms internal resistor Lead resistance which is typic...