E2600 Controller-Drive Tray Installation Guide
125
Things to Know – Lock-Down Codes for the Controller-Drive Tray
Use the following table to determine the diagnostic lock-down code definitions on the Seven-Segment Display in
the controller canister. In general, these diagnostics appear only when the controller is in a non-operational state.
The controller can be in a non-operation state as a result of a configuration problem (such as mismatched controller
types) or as a result of a hardware fault. If the amber Controller Service Action Required LED is on, the
non-operational state is the result of a hardware fault.
Table 42 Supported Diagnostic Lock-Down Codes on the Seven-Segment Display
Diagnostic Code
Description
– –
The firmware is booting.
.8, 8., or 88
This ESM is being held in reset by another ESM.
AA
The ESM A firmware is in the process of booting (the diagnostic
indicator is not yet set).
bb
The ESM B firmware is in the process of booting (the diagnostic
indicator is not yet set).
L0
The controller types are mismatched, which result in a suspended
controller state.
L2
A persistent memory error has occurred, which results in a suspended
controller state.
L3
A persistent hardware error has occurred, which results in a suspended
controller state.
L4
A persistent data protection error has occurred, which results in a
suspended controller state.
L5
An auto-code synchronization (ACS) failure has been detected, which
results in a suspended controller state.
L6
An unsupported host interface card has been detected, which results in
a suspended controller state.
L7
A sub-model identifier either has not been set or has been
mismatched, which results in a suspended controller state.
L8
A memory configuration error has occurred, which results in a
suspended controller state.
L9
A link speed mismatch condition has been detected in either the ESM
or the power supply, which results in a suspended controller state.
Lb
A host interface card configuration error has been detected, which
results in a suspended controller state.
LC
A persistent cache backup configuration error has been detected,
which results in a suspended controller state.
Ld
A mixed cache memory DIMMs condition has been detected, which
results in a suspended controller state.
LE
Uncertified cache memory DIMM sizes have been detected, which
result in a suspended controller state.
LF
The controller has locked down in a suspended state with limited
symbol support.
Summary of Contents for E2600
Page 4: ...iv ...
Page 32: ...24 E2600 Controller Drive Tray Installation Guide ...
Page 36: ...28 E2600 Controller Drive Tray Installation Guide ...
Page 100: ...E2600 Controller Drive Tray Installation Guide 92 ...
Page 138: ...130 E2600 Controller Drive Tray Installation Guide ...
Page 141: ......
Page 142: ...Copyright 2012 NetApp Inc All rights reserved ...