background image

Net.DO 

Lighting Control Equipment Co.,Ltd                                     

   

http://www.netdo.com.cn

 

FOX512 Moving Light Controller.                                                   PAGE: 1 

Contents 

1. Summary

...................................................................................................................... 3 

1.1

 

Functions

......................................................................................................... 3 

1.2

 

Specifications  

(VER: 2.0).............................................................................. 3 

2. Installation

................................................................................................................... 4 

2.1

 

Packing List

..................................................................................................... 4 

2.2

 

Safety Caution

................................................................................................. 4 

2.3

 

Interface and Connection of Controller

......................................................... 4 

2.3.1 Backboard Plot .......................................................................................... 4 
2.3.2 Audio Signal Source................................................................................... 4 
2.3.3 DMX512 Signal Interface & Connection of Fixture..................................... 5 
2.3.4 Power Interface.......................................................................................... 5 
2.3.5 USB Interface ............................................................................................ 5 

3. Operation Guide

.......................................................................................................... 6 

3.1

 

Panel plot

......................................................................................................... 6 

3.2

 

Master Faders

.................................................................................................. 7 

3.3

 

PLAYBACK Area

.............................................................................................. 7 

3.4

 

Function Key (Fixture page 0~2, GROUP, PRESET, SCENE A/B

.............. 7 

3.5

 

SHAPE Control Area

....................................................................................... 8 

3.6

 

Fixture Attribute Key

....................................................................................... 8 

3.7

 

LCD Display, A/B Wheel, Edit Area

................................................................ 9 

4. Quick Start

..................................................................................................................11 

4.1

 

Examples

.........................................................................................................11 

5. Setting Menu

.............................................................................................................. 12 

5.1

 

Menu Operation

............................................................................................. 12 

5.2

 

Library Setting

............................................................................................... 12 

5.3

 

Fixture Setting

............................................................................................... 13 

5.3.1 Fixture Patched........................................................................................13 
5.3.2 Invert attribute value ................................................................................ 15 

5.4

 

Data File

......................................................................................................... 15 

5.4.1 Save File.................................................................................................. 15 
5.4.2 Read File ................................................................................................. 15 
5.4.3 Delete File................................................................................................ 15 

5.5

 

Other Setting

................................................................................................. 16 

5.5.1 Data Initialized ......................................................................................... 16 

6. Manual-Run Fixture

................................................................................................... 17 

6.1

 

Manually-Run Fixture

.................................................................................... 17 

6.2

 

Clear Manual-Run Fixture

............................................................................. 18 

6.3

 

FIND function

................................................................................................. 18 

6.4

 

LOCATE function

........................................................................................... 18 

6.5

 

GROUP function

............................................................................................ 18 

6.6

 

Parity selecting and one by one control of fixtures

................................... 18 

6.6.1 Parity selecting of fixtures ........................................................................ 19 
6.6.2 One by one control of fixtures .................................................................. 19 

6.7

 

FAN function

.................................................................................................. 19 

Summary of Contents for FOX512

Page 1: ...FOX512 MOVING LIGHT CONTROLLER User s Manual Net DO FOSHAN NETDO LIGHTING CONTROL EQUIPMENT CO LTD...

Page 2: ...0 2 GROUP PRESET SCENE A B 7 3 5 SHAPE Control Area 8 3 6 Fixture Attribute Key 8 3 7 LCD Display A B Wheel Edit Area 9 4 Quick Start 11 4 1 Examples 11 5 Setting Menu 12 5 1 Menu Operation 12 5 2 Li...

Page 3: ...n using shape 23 9 Program 24 9 1 HTP and LTP channel 24 9 2 Empty LTP channel 24 9 3 Clear LTP remaining value in Playback 24 9 4 Record Program 25 9 4 1 Single Step Program and Multi Step Program 25...

Page 4: ...by flash or latch SHAPE is provided to control such effects as circles lines and dimmer effect Etc Chase triggered mode selectable Auto1 Auto2 Music Sync LCD display with backlight 12V accessory opera...

Page 5: ...Please mind dust and moist 2 3 Interface and Connection of Controller 2 3 1 Backboard Plot DMX512 Output Audio Input Power Input Power Switch 2 3 2 Audio Signal Source Audio signal can be taken from...

Page 6: ...plug is connected to screen net Two lines of twist line distinguished by different colors are connected to pin 2 and pin 3 of the plug respectively Please do not confuse The schematic diagram for conn...

Page 7: ...Net DO Lighting Control Equipment Co Ltd http www netdo com cn FOX512 Moving Light Controller PAGE 6 3 Operation Guide 3 1 Panel plot...

Page 8: ...n shows the corresponding pages TIPS holding page key can quick flip GO STOP To run or suspend the current connected Multi Step Program STEP Change the running direction of current Multi Step Program...

Page 9: ...Numeric Key Totally 20 Numeric Keys they will have different functions under different status Under Fixture selection status they are Fixture Numeric Key Under GROUP status they are Group Numeric Key...

Page 10: ...selected fixtures to gain the gradual change effect of attribute value among fixtures MODIFY Relative change function of attributes 3 7 LCD Display A B Wheel Edit Area LCD Display Control BACK Used t...

Page 11: ...e the indicators of Numeric Key will show whether there is contents in Playback Group Preset Scene When the indicator is bright it means there is content in that key Fixture Edit CLEAR Used to clear t...

Page 12: ...DmxAddr to A1 Copy the settings of No 1 fixture to No 2 10 fixtures Operation as follows Press and hold COPY Press Fixture Numeric Key 1 Press Fixture Numeric Key 2 10 3 Manual Run Fixture Select No 1...

Page 13: ...PROGRAM SETUP this chapter will introduce the functions of SETUP press SETUP indicator bright to enter settings menu the menu tree of SETUP MENU is as follows 5 2 Library Setting Path SETUP Library Di...

Page 14: ...the fixture model press Modify Soft Key for modification finally press BACK to exit data will be saved automatically Delete libraries can be deleted In Library menu select fixture model press Delete S...

Page 15: ...y COPY Key the DMX addr will be automatically assigned sequentially For example to copy the settings of fixture No 1 to No 2 10 the operation is as follows Press and hold COPY Press Fixture Numeric Ke...

Page 16: ...consoles Path SETUP DataFile 5 4 1 Save File In DataFile menu data can be saved in U disk Insert U disk press SaveFile F1 soft key to enter SaveFile menu then select file name FOX01 99 by Cursor Key...

Page 17: ...ws CLR PB soft key Press and hold for 2 seconds to clear all programs in the console CLR Scene soft key Press and hold for 2 seconds to clear all scenes in the console CLR Patch soft key Press and hol...

Page 18: ...cover the value of the running playback and output to the fixtures The output of playback will not restore until the manual run fixtures are cleared Operation of Manual Run Fixture 1 Select fixtures P...

Page 19: ...ted up without value Dimmer channel will be full and unaffected by Master Faders Only the manually modified data will be saved after exiting TIPS FIND function is recommended in editing Presets or rec...

Page 20: ...is usually used in editing Pan Tilt it can also be used in other attributes such as Dimmer Operation of FAN 1 Select fixtures 2 Press Attribute Key to select attributes 3 Press FAN key its indicator w...

Page 21: ...LIGN key Press Attribute Key Successively Multiple attribute can be selected For example Dimmer Gobo 6 11 Lamp On Lamp Off Reset function Certain fixtures require operation such as Lamp On to their bu...

Page 22: ...ET key to enter preset status indicator above will be bright Press Numeric Key to select presets 7 3 Customize PRESET Preset can be customized 7 3 1 Record PRESET Remark Press CLEAR key before editing...

Page 23: ...onding SHAPE will run automatically Call SHAPE in Chase Just add SHAPE into the Program Step in editing Multi Step Program when the program runs the corresponding SHAPE will run automatically Example...

Page 24: ...he running shape of these fixtures 8 3 Check shape of Reference Fixture Select Reference Fixture press PLAY to enter SHAPE menu it will display the running shapes 8 4 Skill in using shape Example 1 Ci...

Page 25: ...ll be output and kept until next one started if multiple playbacks control a LTP channel at the same time Channels such as Pan Tilt Gobo should be LTP channel normally 9 2 Empty LTP channel When the v...

Page 26: ...pped all fixtures will be recorded if it is skipped Attribute can also be chosen to record Press and hold RECORD select single or multiple attribute by Attribute Key Press Playback Key to finish recor...

Page 27: ...Step10 in Program1 02 in EditStep menu then call the SCENE just recorded 9 6 Delete Program Operation of deleting the whole program is as follow Press and hold DELETE key Press Playback Key of the pro...

Page 28: ...Multi Step Program is triggered by Music rhythm TIPS Differences between internal speed and external speed of Multi Step Program Every Multi Step Program has its own external speed which can be set in...

Page 29: ...sing GO STOP key after it is connected to the control area STEP Running direction of program can be changed by pressing STEP key after it is connected to the control area This key can also be used in...

Page 30: ...ack Path PROGRAM FadeSync Enter FadeSync menu as shown on the right Select program by Playback Key the following items of Fader Synchronization can be open close LTP Sync When it is on LTP channel val...

Page 31: ...nes superimposed Delete Scene Press and hold DELETE Press Scene Numeric Key to finish deleting Copy Scene Press and hold COPY Press Scene Numeric Key source Press another Scene Numeric Key target The...

Page 32: ...hannels will output the value of SCENE It means SCENE can superpose on Playback playback will restore outputting after SCENE is cancelled Priority of Manual Run Fixture Manual Run Fixture is of the hi...

Page 33: ...rotection menu as shown on the right Data Lock If user doesn t hope the data in console to be modified by others set the Data Lock status to be on After this operation the data in console can only be...

Reviews: