50
neSS D24 Control Panel - inStallation & PrograMMing Manual
audiblE mONiTOriNg
P54e 2e enabled
While Central Station Monitoring is recommended, the D24 can also send audible
voice alarm reports to any telephone. the audible voice message repeats the
word "alarM".
repOrtIng sequenCe
When triggered by an alarm event the D24 will call the Primary telephone number
(P51e) and then commence the audible message, the audible message will
continue for 45 seconds or until it is acknowledged by the # key on the telephone.
if there is more than one alarm message to transmit, after it has received the
Kiss-off/ acknowledge tone it will commence transmission of the next message.
the D24 should continue to do this until all alarm messages are transmitted and
Kissed-off.
aCKnOwledge tOne
the person receiving the call can then acknowledge the alarm by pressing the
key on their telephone. Press the
key for at least 2 seconds during pauses in
the audible message.
Audible Voice format is available in
D24 V1.5 and later.
mONiTOriNg
CENTral STaTiON mONiTOriNg
P54e 3e enabled (Default)
the ness D24 control panel has an on-board digital dialler which can send
detailed alarm messages to a Central Monitoring Station.
the digital messages can include information about the zone/s which caused the
alarm, tamper alarms, low battery or mains failure reports, and it can also (by user
number) identify the users who arm and Disarm the system.
Central Station Monitoring is highly recommended and is the most effective
method of monitoring your alarm system.
installers are welcome to contact ness for further information about monitoring.
MONITORED
PREMISES
CENTRAL STATION MONITORING
TELEPHONE LINE
MONITORING
STATION
MONITORED
PREMISES
AUDIBLE MONITORING
TELEPHONE LINE
ANY TELEPHONE