49
O P E r a T i O N
oP
neSS D24 Control Panel - inStallation & PrograMMing Manual
TEST mOdE
test Mode allows the user to manually test all audible and visual outputs without
alarming the panel.
In normal operating mode, Press...
[CoDe]
The icon will turn on.
Press the keys below to operate each output. Press the same key to turn the output
off. Pressing any other key will test that output and cancel the current output.
Press...
To exit Siren test mode.
keY
INDICAtor
oUtPUt
1
1
Siren a, tone 1
2
2
Siren B, tone 1
3
3
reSet (internal screamer)
4
4
StroBe
5
5
auX 1
6
6
auX 2
7
7
KeyPaD BeePS
8
1
Siren a, tone 2
9
2
Siren B, tone 2
TEST OPTiONS
P45e 1e INStALLAtIoN WALk teSt moDe.
this test runs in installer program mode while P45e 1e is selected. outside of
installer program mode, the test is supended but the zone selection remains.
on: installation Walk test Mode is enabled.
to enter test mode, press
P45e 1e
the icon will fast flash.
[zone number] e, [zone number] e
... select (or de-select) the zones to test
as each zone is selected, the corresponding zone icon will turn on.
each test zone will now, on going unsealed, cause its zone indicator to fast flash
and the reset output to give a 2 second burst.
to cancel the walk test press the
e
button.
to restart the walk test, press
1e,
the icon will resume flashing. the previously
selected test zones will be on.
P45e 2e AUtomAtIC ZoNe teSt.
this test can identify potentially faulty detection devices by alerting the user to
zones which have not unsealed during the past 20 arm and Disarm cycles.
if selected, the test runs during the normal operation of the panel.
if any non-24hr zone/s does not unseal during 20 arming cycles, the D24 will alert
the user by turning on the icon.
you can view the offending Zone(s) by pressing
VIeW 7
. the offending zone(s)
icons will be on.
to clear the Zone test label, unseal the offending zone(s) while still in the
VIeW 7
mode. this will result in the steady zone icon changing to a fast flash. this will
verify whether the zone is functioning correctly or not.
to cancel the display press the
e
button.
if the icon remains on, press
VIeW 7
then
e
.
this section is repeated on page 26.