![Neptune TRU/FLO Installation And Maintenance Manual Download Page 51](http://html1.mh-extra.com/html/neptune/tru-flo/tru-flo_installation-and-maintenance-manual_1668257051.webp)
Appendix C
TRU/FLO Compound Meter Installation and Maintenance Guide
39
3
Make sure the o-ring inside the main valve assembly is in good
condition and does not have any nicks or cuts. See Figure 57.
4
Replace the o-ring if needed.
Figure 57 O-ring
5
After checking the retainer ring, the o-ring, and the integrity of the
main valve, the parts can be reinstalled. See Figure 58.
Figure 58 Reinstalling the Parts
6
Reinstall the retainer ring on the main valve and tighten the four
screws. See Figure 59.
Figure 59 Secure Retainer Ring
If the o-ring is damaged, a failed low flow test could result.