Maintaining the TRU/FLO Compound Meter
TRU/FLO Compound Meter Installation and Maintenance Guide
19
Replacing the T-10 Chamber
Complete the following steps to replace the T-10 chamber.
1
Replace the chamber o-ring if necessary.
2
Add the T-10 strainer making sure to align the tab of the strainer
with the groove in the T-10 chamber. See Figure 23. Make sure the
screen is flush with the T-10 chamber.
Figure 23 Adding the T-10 Strainer
3
Place the T-10 chamber with the T-10 strainer in the cover
assembly with the magnet facing down. See Figure 24.
The strainer holds the chamber in place and seals the chamber O-
ring against the mating surface in the maincase.
Figure 24 Placing the T-10 Chamber
4
Add the chamber gasket to the T-10 chamber. See Figure 25 and
Figure 25 T-10 Chamber Gasket
Figure 26 Replacing the Gasket
Tab