Hangzhou NeoDen Technology Co.,Ltd.
19
Figure (2.1.5.2-1)
Function: mainly used to set up the picking up information of IC tray and vibration feeders,
through change parameter information to finish the picking components’ work on the special
stacks.
horizontal numbers: mainly means how many components on X direction (A row has several
columns of components)
vertical numbers: mainly means how many components on Y direction (A column has
several rows of components)
X Y location on top right corner: finding the component which is the most closed to top right
corner in this area by location (generally, this component would be the last one in this IC
matrix, of course the first beginning component is located on the most closed to down left
corner)
the first beginning location X Y: after all above projects are confirmed, the complete default
setting is X 1 Y 1 in IC tray ( means the first column and the first row), if meet this situation, a
part of components on the IC tray are already used , X Y can be set up directly ,through XY
information, X means column Y means row , which can confirm a new picking location in this
way.
●
the basic information of stack: see figure (2.1.5.2-2)
Figure (2.1.5.2-2)
Figure (2.1.5.2-3)
skip place option: if tick this option, all components will be skipped on this stack, according
to actual situation to choose, and Also can be exchanged via exchange stack
firstly, align the location of components on this stack, see figure (2.1.5.2-3) after alignment,
click “save”, then the XY picking will collect data automatically and display aligned value.
pick height: the down and up height can be controlled by the alongside height testing bar to
collect nozzle height data. The place height can be adjusted slightly based on the thickness of
tape reel.
move speed: this value can control the mounting speed directly
initial angle: The default angle is 90 degree, which can change the angle here in special
Summary of Contents for 7