8.5 TILT/TURN axes in MANUAL mode
In TILT/TURN axes function the axes are interdependent. If one axis is tilted
the other axis is simultaneously turned.
CAUTION!
The laser head setting has reached the maximum value ±5°. The rotating laser beam,
the red LED in the control panel and the warning symbol in the display flash.
f
Press the arrow buttons once or several times until the LED and the warning
symbol disappear. The rotating laser lights up again continuously.
TILT X axis without % information
HVA2N
Invoke TILT function,
press button once
X axis symbol is
displayed
Use buttons to tilt X axis in direction of
arrow
Y-Achse NEIGEN without % information
HVA2N
Invoke TILT function,
press button twice
Y axis symbol is
displayed
Use buttons to tilt Y axis in direction of
arrow
NOTE
f
Primus 2 HVA2N must be operated in the MANUAL mode.
8.6 Tilt monitoring
The Primus 2 HVA2N includes tilt monitoring, i.e. the actual tilt of the laser
plane is continuously compared with the specified value (Chapter 8.3). If
necessary, the tilt is readjusted, so that the actual tilt is always the same as
the specified tilt. The readjustment is made within the scope of the given tole-
rance (Chapter 3.2).