Control items
Result
Connection – GND1
Connection – power cable, check tightness
Lightning conductor
Compressed air
Air lines cleaned
Air pressure (6–10 bar, 87–145 PSI)
Clean and dry air (ISO 8573-1, class 5)
Compressed air valve
Compressed air connected to unit
Ground check measurement
Check (≤100 ohm):
•
GND1 – Fan
Check (≤10
5
ohm):
•
Incoming duct – Incoming mains ground
•
GND1 – External mains ground
Accessories (if applicable)
Signs and warnings
Intended use marked or indicated
Safe bag replacement described or indicated
Initial start-up (function test)
Maintenance switch
Automatic start and stop (standby and reset switch), if fitted
Vacuum limiting valve (both, if two are fitted)
Motor, direction of rotation
Time spent in Y mode
Automatic filter cleaning
Manual filter cleaning
Cover on the start and control unit fitted
Summary of Contents for E-PAK 500
Page 2: ...E PAK 500 2 ...
Page 8: ...E PAK 500 8 800 mm 3 5 150 mm 6 2 3 4 2 3 1 ...
Page 9: ...E PAK 500 9 4 4 2 5 6 3 7 1 11 12 10 8 9 ...
Page 10: ...E PAK 500 10 5 1 2 3 4 5 6 7 8 667 C C 1174 C C 11 6 ...
Page 11: ...E PAK 500 11 7 8 1 2 4 3 1 13 14 15 3 5 6 7 4 16 8 9 10 11 2 17 12 ...
Page 12: ...E PAK 500 12 0 I RESET MANUAL START MANUAL FILTER CLEANING 9 10 11 ...
Page 13: ...E PAK 500 13 14 15 16 12 13 ...
Page 14: ...E PAK 500 14 17 ...
Page 15: ...E PAK 500 15 18 ...
Page 16: ...E PAK 500 16 19 ...
Page 17: ...E PAK 500 17 20 ...
Page 56: ...E PAK 500 CS 56 SSR Relé pro spuštění a vypnutí ...
Page 385: ...E PAK 500 385 ZH SSR 启动 停止继电器 TS 热控开关 SSR 启动 停止继电器 ...
Page 390: ...E PAK 500 ZH 390 ...
Page 391: ......
Page 392: ...www nederman com ...