38
NED
RCDL2K20CL
UME-0115-02
When the exposure time is set, there will be cases where the exposure time and the
already set scan rate do not satisfy the above equation. In this case, the camera will
adjust the scan rate without reporting an error (the camera will automatically adjust the
scan rate). This automatically adjusted scan rate can be displayed by pressing the Get
Current Value button.
4.2.16 Memory Initializing (Initializing Camera Settings)
Reset the flash memory to the factory default.
⚫
Format 1
CMD CR
⚫
CMD
rst
<Example>
rst
>OK
>Model=RCDL2K20CL
>Ver.=0.60_0xff08
>Serial=0
>gax 0
>gdx 0
>gdxr 0
>gdxg 0
>gdxb 0
>odx 0
>odxr 0
>odxg 0
>odxb 0
>inm 0
>prd 2640
>expo 376400
>rev 0
>tpn 0
>ffcm 0
>ffct 800
>colmtx 0
>krr 1000
>krg 0
>krb 0
>kgr 0
>kgg 1000
>kgb 0