background image

6

USER INSTRUCTIONS

• ALWAYS USE A FIREGUARD WHEN OPERATING THE FIRE IN THE PRESENCE OF

CHILDREN OR THE INFIRM

• ENSURE THAT CURTAINS CANNOT BLOW ACROSS THE FIRE OPENING ENSURE THAT

THE CHIMNEY OR FLUE IS NOT BLOCKED

• WASH HANDS AFTER HANDLING COALS AND ENSURE CHILDREN DO NOT HANDLE

THEM AS THE COLOURING MAY CONTAIN TOXIC DYES

GAS FITTING REGULATIONS

The installation of gas appliances is covered by gas fitting regulations in most States which specify

that any gas appliance shall only be installed by authorised personnel. Installation by an

unauthorised person is an offence under these regulations and could lead to cutting off of gas

supply and prosecution.

LIGHTING

Please read carefully before attempting to light your fire for the first time.

Your fire is fitted with a safety gas tap, Piezo igniter, pilot, flame failure and oxygen depletion

device. To turn the fire on, ensure that the gas supply is on, turn the gas knob to (*),depress the

gas knob and while still depressing the knob, push the Piezo igniter button until the pilot is alight.

Keep the gas knob depressed for 20 seconds after the pilot has lit.(The first time that the unit is

used it may take longer for the pilot to light as you will have to wait for gas to fill the line). Release

the gas knob and check that the pilot stays alight. If it does not, repeat the above procedure. If the

pilot does not stay alight contact the supplier. Once the pilot is alight you may turn the gas control

knob to the high setting (7) . The fire will ignite from the pilot. If required you may now turn the gas

control knob back to the pilot setting (*). The fire will extinguish leaving only the pilot on. Take care

not to turn the pilot off as well. A slight resistance is felt before the fully off position. If the pilot is

turned off do not try to light it for about a minute as a safety interlock times until unit has cooled

down.
It is advisable that if the fire is to be left for extended periods, the gas control knob should be

turned back to the off setting. To relight, follow the procedure from the beginning.
PLEASE NOTE: do not operate your fire at the maximum setting for more than a few minutes in

the first eight hours following installation. This will avoid thermal shock to the coals and burner

surface. The new coals may give off a burnt odour during this period. Any minor surface cracking

of the burner or the coals is normal and is not a cause for concern. If you think that the burner may

have been damaged by misuse or accident at any time, please call your supplier/installer for

service. Before removal of any part of the fire, ensure that the fire is cold.

SERVICE

The appliance should require little maintenance. Periodically check that the chimney is drawing

properly and that no debris has fallen into the appliance. If the flames are very small or the pilot not

functioning, it may be due to dirt in the lines, but this must be serviced by an authorised gas fitter.

Summary of Contents for WONDERFIRE AF18

Page 1: ...tified as a Space Heater WONDERFIRE AF18 OF MANUAL VALVE INSTALLATION OPERATING MANUAL Nectre Wonderfire fire boxes are approved to be installed as a zero clearance firebox and are designed to operate...

Page 2: ...tructions or b it has been installed in an outdoor setting 4 Limit of Liability The warranty provided under this warranty is limited to replacement or repair of the Gas Burner only at our option To th...

Page 3: ...THE APPLIANCE OR DRAUGHT OF CHIMNEY OR FLUE DO NOT MODIFY THIS APPLIANCE THIS APPLIANCE IS DESIGNED TO OPERATE WITH LUMINOUS FLAMES THIS MAY EXHIBIT SLIGHT CARBON DEPOSITS Permanent ventilation of th...

Page 4: ...4 CONTENTS Contents 4 Data Plate 5 Dimensions 5 User Instructions 6 Installation Instructions 7 Servicing Details 9 Fault Finding Chart 10 Glen Dimplex contact information 12...

Page 5: ...the unit for reference to gas pressure consumption 5 AF18 OF Manual valve Eurosit 630 Gas Injector Size mm TPP N G C Mj Hr Natural Gas 1 x injector multiport 7 ports x 1 25 0 5kPa high 0 35kpa Low 35...

Page 6: ...not stay alight contact the supplier Once the pilot is alight you may turn the gas control knob to the high setting 7 The fire will ignite from the pilot If required you may now turn the gas control...

Page 7: ...erall dimensions of the fire is 465mm wide front 325mm wide rear x 240mm Deep x 320mm high See below for minimum fire place dimensions The appliance may be installed in an existing open fireplace as a...

Page 8: ...d be fixed to the base of the fireplace with a screw to each front corner of the burner Gas Gas connection is to a BSP male fitting connected to the RHS of the valve It is located 100mm from front 45m...

Page 9: ...he burner and place upside down on a flat surface covered with old newspaper BURNER To access the burner remove the coals The burner is glued in to the burner tray Examine it for any damage and check...

Page 10: ...et blocked Gas pressure too low Tighten at rear of valve Replace Oxypilot Blow clean out Pilot runs off mains pressure which must be at least 1 135 Kpa Gas will not ignite After turning off Time safet...