background image

3

INSTALLATION NOTICE

The installation of this appliance is only to be carried out by an authorised person in accordance

with the Manufacturer’s Instructions, local gas fitting regulations, AS/NZS5601.1-2013 installation

code for gas burning appliances and any other relevant statutory regulations. 

In all cases the installation of this appliance shall meet the requirements as set out in 

AS/NZS5601.1-2013

NOTE: A slight smell may be apparent for the first few hours of use. This is due to the heat resistant

paint curing. It is recommended to open windows in the room for the first lighting of the fire. In

some instances a slight discolouration may occur inside the firebox.  This is a normal condition

and is not covered by warranty.

IMPORTANT SAFETY NOTICES

DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.
DO NOT USE OR STORE FLAMMABLE MATERIAL NEAR THE APPLIANCE.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILST IT IS IN OPERATION.
CARE MUST BE TAKEN TO ENSURE THAT ANY RETURN AIR REGISTER OR EXHAUST SYSTEM

DOES NOT ADVERSELY AFFECT THE OPERATION OF THE APPLIANCE OR DRAUGHT OF

CHIMNEY OR FLUE.
DO NOT MODIFY THIS APPLIANCE.
THIS APPLIANCE IS DESIGNED TO OPERATE WITH LUMINOUS FLAMES. THIS MAY EXHIBIT

SLIGHT CARBON DEPOSITS.

Permanent ventilation of the room where the fire is to be situated is essential while fire is in operation.

The room must have a minimum cross sectional area of 40,000sq mm of effective ventilation.

It is recommended that you service your gas fire every 2 years.

VENTILATION REQUIREMENTS

THIS IS PRIMARILY A DECORATIVE APPLIANCE AND IS NOT CERTIFIED AS A SPACE HEATER.

WARNING

This firebox has a naked flame, care should be taken when it is operating if children or the infirm are in close

proximity.  For protection of young children or the infirm, a secondary guard is required. A safety screen is

recommended if constant supervision is not possible. It is recommended that a secondary guard complying

with AS-NZS2286 be installed.
The appliance is not intended for use by persons (including children) with reduced physical, sensory or

mental capabilitites, or lack of experience and knowledge, unless they have been given supervision or

instruction concerning use of the appliance by a person responsible for their safety. Children should be

supervised to ensure that they do not play with the appliance.

Summary of Contents for WONDERFIRE AF18

Page 1: ...tified as a Space Heater WONDERFIRE AF18 OF MANUAL VALVE INSTALLATION OPERATING MANUAL Nectre Wonderfire fire boxes are approved to be installed as a zero clearance firebox and are designed to operate...

Page 2: ...tructions or b it has been installed in an outdoor setting 4 Limit of Liability The warranty provided under this warranty is limited to replacement or repair of the Gas Burner only at our option To th...

Page 3: ...THE APPLIANCE OR DRAUGHT OF CHIMNEY OR FLUE DO NOT MODIFY THIS APPLIANCE THIS APPLIANCE IS DESIGNED TO OPERATE WITH LUMINOUS FLAMES THIS MAY EXHIBIT SLIGHT CARBON DEPOSITS Permanent ventilation of th...

Page 4: ...4 CONTENTS Contents 4 Data Plate 5 Dimensions 5 User Instructions 6 Installation Instructions 7 Servicing Details 9 Fault Finding Chart 10 Glen Dimplex contact information 12...

Page 5: ...the unit for reference to gas pressure consumption 5 AF18 OF Manual valve Eurosit 630 Gas Injector Size mm TPP N G C Mj Hr Natural Gas 1 x injector multiport 7 ports x 1 25 0 5kPa high 0 35kpa Low 35...

Page 6: ...not stay alight contact the supplier Once the pilot is alight you may turn the gas control knob to the high setting 7 The fire will ignite from the pilot If required you may now turn the gas control...

Page 7: ...erall dimensions of the fire is 465mm wide front 325mm wide rear x 240mm Deep x 320mm high See below for minimum fire place dimensions The appliance may be installed in an existing open fireplace as a...

Page 8: ...d be fixed to the base of the fireplace with a screw to each front corner of the burner Gas Gas connection is to a BSP male fitting connected to the RHS of the valve It is located 100mm from front 45m...

Page 9: ...he burner and place upside down on a flat surface covered with old newspaper BURNER To access the burner remove the coals The burner is glued in to the burner tray Examine it for any damage and check...

Page 10: ...et blocked Gas pressure too low Tighten at rear of valve Replace Oxypilot Blow clean out Pilot runs off mains pressure which must be at least 1 135 Kpa Gas will not ignite After turning off Time safet...