background image

 

 

 

 

First few times the appliance is lit, it will give off some 
odorous fumes. This is caused by the paint curing. 

Do not touch the paint work while it is curing otherwise it 
can leave a permanent mark on the appliance. 

Once the paint has cured it will not re-occur. 

Keep the room well ventilated until these fumes have 
cleared. 

 

 

 

Burn only seasoned softwood timber with a moisture 
content of less than 25% (dry basis) 

Newly cut wood should be allowed to dry/season for 12 
months before use. 

Wood should be stored in an environment protected from 
the weather to minimise any potential moisture content. 

For best results, wood should not exceed 270-300mm in 
length and 150mm diameter. Any larger and appliance will 
not operate at its optimum. It is better to burn several 
smaller pieces of wood than one large single piece.  

Poor quality timber: 

-

 

Causes low combustion efficiency 

-

 

Produces poor emissions (smokey) 

-

 

Results in additional build-up of creosote (soot) in 
the flue which will then require regular cleaning 
and may result in a flue fire. 

Do not burn painted, impregnated/treated wood, 
manufactured board products or pallet wood.

 

 

 

 

1.

 

Place firelighters and/or paper and dry kindling wood in 
the base of the firebox. 

2.

 

Open the air control by pulling it all the way out 

3.

 

Light the paper or firelighters. 

4.

 

Once the fire has taken hold add larger pieces of 
wood. For optimal burn conditions, place the logs in a 
front to back orientation (right angles to the door 
opening). Too many logs may smother the fire. 

5.

 

Once the fire is established, adjust the air control to 
the relevant position for the required heat output. 

 

 

High heat output:

 

 

After establishing the fire and loading it with larger 
pieces of wood, leave it running with the air control 
fully open.  

 

Note that this setting is not the most energy efficient 
as some heat is lost up the flue instead of being 
transferred into the room. 

 

 

Running the appliance with the door open will not 
produce maximum heating in the room as it will draw 
a lot of already warmed air out of the room.

 

 

Do not overload firebox with fuel.

  

 

Low heat output:

 

 

The heat output of the heater can be reduced by 
closing the air control (slide handle to the right) which 
will restrict the oxygen supplied to the fire thereby 
slowing down the rate at which the wood burns.  

 

This setting will provide the best energy efficiency as 
the wood burns for longer. However, if not operated 
correctly may result in higher particulate emissions.

 

 

Prior to closing the air control

 ensure that the fire is 

burning briskly. This may require leaving the air 
control fully open for 10-15mins before shutting 
down. 

 

For the optimum between clean burning, and getting 
the best in efficiency from the heater, from the fully 
closed position, open the air control a couple of 
millimetres. 

The air control can be adjusted to any position so desired 
depending on wanted heat output versus burn time. 

 

Reload with more wood: 

1.

 

Open air control before opening door. 

2.

 

Rake / break up any existing coals. 

3.

 

Load the wood with the length orientated front to back. 

4.

 

Better results will be achieved by loading several 
smaller pieces of wood rather than one large piece. 

5.

 

Close door with air control fully open, and leave for 
minimum of 10 minutes to allow the fresh wood to 
catch. 

6.

 

After 10 or more minutes, the air control can be 
adjusted to the desired heat output setting. 

2. USING APPLIANCE FOR FIRST TIME 

3. RECOMMENDED FUELS 

4. LIGHTING THE FIRE 

5. RUNNING THE APPLIANCE 

Summary of Contents for N65

Page 1: ...Fax 09 274 8472 Email sales glendimplex co nz Web www glendimplex co nz Glen Dimplex New Zealand Ltd reserves the right to change specifications the content of this manual or the design of its product...

Page 2: ...TYPES OF PRESERVATIVE TREATED WOOD AS A FUEL CAN BE HAZARDOUS The appliance or flue system should not be modified in any way without the written approval of the manufacturer Extractor fans or cooker h...

Page 3: ...fter establishing the fire and loading it with larger pieces of wood leave it running with the air control fully open Note that this setting is not the most energy efficient as some heat is lost up th...

Page 4: ...ore detail Depending on the type of wood burnt and frequency the ashes will need removing every 2 to 6 weeks Excess ashes should be removed when necessary placed in a non combustible container such as...

Page 5: ...i Burning unseasoned wood if the wood is too wet it will cause the glass to blacken ii Appliance operated at low temperature after an overnight burn where the air slide control has been fully closed t...

Page 6: ...the bottom of the pin To replace the door glass i The door glass is held in position by the rectangular glass retainer fixed by four M6 screws two at the top and two at the bottom ii With 4mm allen ke...

Page 7: ...fastening the latch to the side of the firebox body Gently tap the latch only a millimetre to start with Retighten the screws and test for any improvement If no improvement repeat process until door c...

Page 8: ......

Page 9: ...r feedback on the following questionnaire Question Please tick appropriate remark 1 General presentation of Product Excellent Good Ok Needs to Improve 2 Styling and Looks Excellent Good Ok Needs to Im...

Page 10: ......

Page 11: ...port or travel costs Consumers may have additional rights under the Consumer Guarantees Act 1993 New Zealand or the Australian Trade Practices Act 1974 including the Australian Consumer Law Conditions...

Page 12: ...left the control of Glen Dimplex Direct indirect or consequential losses or special damages of any kind including costs of collection and delivery other than repair or replacement of products or compo...

Reviews: