![Necta Korinto UL Installation, Use And Maintenance Manual Download Page 9](http://html1.mh-extra.com/html/necta/korinto-ul/korinto-ul_installation-use-and-maintenance-manual_3827856009.webp)
5
© by N&W GLOBAL VENDING SpA
07 06 274 -00
Chapter 1
LOADING AND CLEANING
POWER SUPPLY SWITCHES
Main
A main switch is fitted outside the machine, disconnecting
the power from the machine without having to open the
door.
The terminal strip supporting the line cable, the fuses
and the noise suppressor stay energised in any case.
Door
When opening the door a special switch disconnects the
power from the machine electrical system to allow the
operations described below, regarding loading and routine
cleaning, in full safety.
Top panel
Also when opening the machine top panel, a switch
disconnects the power, allowing loading operations in a
safe condition.
All operations requiring the machine to be energized
should be carried out EXCLUSIVELY by qualified per-
sonnel, informed about the specific risks of such
situation.
HYGIENE AND MAINTENANCE
According to current safety and health rules and regula-
tions, the operator of an automatic vending machine is
responsible for the hygiene of materials that come in
contact with foodstuff; therefore he must carry out mainte-
nance on the machine to prevent the formation of bacteria.
At installation the hydraulic circuits and the parts in
contact with foodstuff should be fully sanitised to
remove any bacteria which might have formed during
storage.
The machine is not suitable for outdoor installation, it must
be installed in a dry room where the temperature remains
between 2° C and 32° C.
It is advisable that specific sanitising products are used for
cleaning also the surfaces which are not directly in contact
with foodstuff.
Some parts of the machine can be damaged by strong
detergents.
The manufacturer declines all responsibility for damage
caused by non-compliance with the above instructions or
by the use of strong or toxic chemical agents.
Before starting any maintenance operations requiring
parts of the unit to be removed, the machine must
always be switched off.
Do not use sprayed water for cleaning the machine.
Fig. 3
1 - Tray detection switch
2 - Tilting cup support
3 - Coffee unit
4 - Door switch
5 - Coffee funnel
6 - Grinding adjustment knob
7 - Chute for decaffeinated coffee
8 - Top panel switch
9 - Machine top panel
10 - Coffee beans hopper
11 - Instant prod. container
12 - Coffee container shutter
13 - Instant prod. mixer
14 - Spouts tray release button
15 - Liquid waste tray
16 - Main external switch
Summary of Contents for Korinto UL
Page 2: ......
Page 4: ......
Page 49: ...by N W GLOBAL VENDING SpA NOTE...
Page 50: ...N W GLOBAL VENDING S P A Sx44100...
Page 51: ...Korinto ES UL 120V...
Page 52: ...by N W GLOBAL VENDING SpA NOTE...
Page 53: ...by N W GLOBAL VENDING SpA NOTE...
Page 54: ...by N W GLOBAL VENDING SpA NOTE...
Page 56: ......