background image

5 9

© by NECTA VENDING SOLUTIONS SpA

01 10 126-03

Decimal point.
 "x" is the number of the display digit (1-4) where the
decimal point is shown. With x=1 this point is not displayed;
to have two decimal digits displayed, enter x=3. In serial
operating mode also this information is transmitted directly
to the control board.

Ux - coins accepted by the validator.
This function is used only when the control board is
interfaced with a coin validator.
Multiply the basic coin value by "xx", to assign the value to
the six coins. For example, if the basic coin is set to 1 (Sc
1):

(1st coin)

U1 x=5

5x1

= 0.05

(2nd coin)

U2 x=10

10x1 =  0.10

(3rd coin)

U3 x=20

20x1 =  0.20

(4th coin)

U4 x=50

50x1 = 0.50

5th coin)

U5 x=100

100x1 = 1.00

(6th coin)

U6 x=200

200x1 = 2.00

Credit mode (validators only)
This function is used to make available to the user any
amount exceeding the selection price
0 = excess cashed
1 = excess made available
2 = excess made available for a programmed time; confirm
this option to access function 

  which allows

programming of such time for up to a maximum of 99
seconds.

Maximum credit (only validators and MDB )
The maximum credit (expressed in number of basic coins)
accepted by the coin mechanism is displayed . If such
value is set to 0 this function is ignored.

Sales prices per selection.
"xxxx" is the price value of a selection; the selection button
to which the price is referred is illuminated. The maximum
value is 255 times the basic coin (ex. Sc = 1, Max price  =
1*255 = 2.55).

Maximum change (MDB only)
It is the value of the maximum amount of change returned.
If set to 0 the maximum possible value is returned.

Multiple sales (MDB only)
This function is used to make available to the user any
amount exceeding the selection price.
0 = change returned after each selection
1 =  change returned only after pressing the button

Accepted coins (MDB only)
The MDB protocol allows acceptance of 16 coins:
XX = 1 to 16
 Y = 0 = disabled
 Y = 1 = enabled
The actual number of usable coins depends on the coin
mechanism installed.

Machine code
The machine is identified by a 6-digit code, useful in the
case of automatic data collection.
"x" is the value (0 to 9) which can be assigned to the digits
(1 to 6).

Counters display
This function enables the possibility of displaying or not the
total selection counter when switching the machine on.
x=0

Function disabled

X=1

Function enabled

Control of cycle start time.
This function is not used for this machine, therefore it
MUST be set to ZERO.

Time-out.
It controls the maximum operating time (expressed in
seconds) of the dispensing motors. If such time is ex-
ceeded, the control board stops the motor and switches the
appropriate "empty" warning lamp on. The "empty" condi-
tion is recorded and the selection is blocked until it is reset
(see paragraph "motor reset ").

Initialising
This function is used in the case of stored data error or when
replacing the EPROM. All statistical data will be reset.
Press the confirm button 3 and the prompt message

 to confirm will be displayed.

Press again button 3 and initialising will start; press button
4 to cancel the initialising routine.

Place minidip 1 back to position "OFF" to return to the
normal operating mode.

Summary of Contents for Zeta CB Series

Page 1: ...MANTENIMIENTO INSTALLATION BEDIENUNG WARTUNG HANDBOEK VOOR GEBRUIK INSTALLATIE ONDERHOUD IT Italiano Pagina 1 FR Fran ais Page 21 UK English Page 41 ES Espa ol P gina 61 DE Deutsch Seite 81 NL B Nede...

Page 2: ......

Page 3: ...a de identificaci n resulta conforme a las disposiciones legislativas de las directivas 89 392 89 336 73 23 CEE y modificaciones y integraciones sucesivas Declara que o distribuidor descrita na chapa...

Page 4: ......

Page 5: ...PAGE 4 POWER CONSUMPTION PAGE 4 VARIABLE COMBINATION LOCK PAGE 45 LOADING AND CLEANING PAGE 45 DOOR SWITCH PAGE 45 DISPENSING MODULES PAGE 45 CONTROLSAND INFORMATION PAGE 47 LOADING PAGE 47 RELEASING...

Page 6: ...hine Thereforeitmustalwaysfollowthemachine whenitis moved or ownership is transferred so that different operators may be able to consult it Beforeinstallingandusingthemachine itisfirstnecessary tocare...

Page 7: ...sons caused by incorrect installation Theintegrityofthevendingmachineanditsconformity with the rules and regulations in force for its relevant systems must be checked by qualified personnel at least o...

Page 8: ...l o v y l p p u S 0 3 2 0 3 2 0 3 2 z H y c n e u q e r f y l p p u S 0 5 0 5 0 5 W r e w o p d e l l a t s n I 0 5 7 0 5 7 0 0 8 V p m a l t r o h s r o o D 0 3 2 0 3 2 0 3 2 W p m a l t r o h s r o...

Page 9: ...icro switchdisconnects the power from the electrical system of the machine to allowtheloadingandroutinecleaningoperationsdescribed below in full safety All operations requiring the machine to be energ...

Page 10: ...o switch 5 Limit micro switch Fig 7 1 Double column 2 Single column 3 Rotor The columns can be preset for dispensing 66 dia cans or round bottles with a diameter range of 62 to 73 mm Warning glass bot...

Page 11: ...the chute inlet and let them roll down It is not important which side the top of the can is facing Should a product chute be completely empty for ex whenfirstinstallingthemachine afterloadingmakea sel...

Page 12: ...ATURE CONTROL Thethermostatisinitiallyadjustedsothatatemperatureof 1 5 Cismaintainedinthelowerportionoftherefrigerated box containing bottles and cans which will be sold first The thermostat is locate...

Page 13: ...outlet remove all products from the columns and clean the inside and all accessories INSTALLATION The machine installation and the following maintenance operations should be carried out with the machi...

Page 14: ...the power cable should be made by qualified and suitably trained personnel only using cables type HO5 RN F HO5 V V F or H07 RN F with a 3x1 5 mm2 section Do not use adapters multiple sockets and or e...

Page 15: ...s 2 65 66 67 mm thickness 3 68 69 70 mm thickness 4 Short adapting plate 5 Long adapting plate The rotor insert can be identified by the dispensed product diameter printed on the element To install or...

Page 16: ...LEMENTS The anti friction elements are frames made of special plastic material which facilitate product sliding For dispensing bottles the anti friction elements are fitted onthedoublecolumnbafflesand...

Page 17: ...mn back panel BOTTLE GUIDES FOR SINGLE COLUMNS The bottle guides have the function of keeping bottles with a tapered neck correctly aligned so that they do not tilt forward Forsinglecolumns theguidesa...

Page 18: ...hrough an opening with a width less than the smallest dimensionofthemachine thedoorandthedoorframecan be removed to temporarily reduce the depth to 750 mm The disassembly and reassembly operations mus...

Page 19: ...validator Serial interface for MDB coin mechanism Programming of the number of selections 1 to 10 Programming of the vending price for each single selection Time out function for the vending motors a...

Page 20: ...lection is blocked the corresponding button is illuminated Whenpressingtheilluminatedbutton thedisplayindicates if the cause of the blockage is an empty module and ifthecauseisaproblemconnectedwiththe...

Page 21: ...machine code 6th digit of machine code Time of cycle start Motor safety time 0 to 30 seconds Initialising Countersdisplay The setting sequence of the parameters varies according to the type of interfa...

Page 22: ...se minimum 1 maximum 10 columns then press button 2 to store the new data unit and go to the next parameter x is the number of selections It can be set to values varying from 1 to 10 default 6 Type of...

Page 23: ...e MDB only It is the value of the maximum amount of change returned If set to 0 the maximum possible value is returned Multiple sales MDB only This function is used to make available to the user any a...

Page 24: ...n 2 each time the illuminated button indicates the selection to which the value on the display is referred Toresetavaluepressbutton5 thedisplaywillberesetand the next data unit will automatically be d...

Page 25: ...BOARD SM CONTROL BOARD ST STARTER TERM THERMOSTAT TR TRANSFORMER TX DELAYED FUSE X COURRENT SIGLA DENOMINACION MEMORIA ESQUEMA ELECTRICO BDV CONNECTOR PARA MONEDERO BDV CF CONDENSADOR DEL FILTRO COM C...

Page 26: ...NECTA VENDING SOLUTIONS SpA Sx34002...

Page 27: ...Zeta 550 9...

Page 28: ...NECTA VENDING SOLUTIONS SpA Sx34400...

Page 29: ...Zeta 550 6...

Page 30: ...NECTA VENDING SOLUTIONS SpA Sx34700...

Page 31: ...Zeta 450 5...

Page 32: ...NECTA VENDING SOLUTIONS SpA Sx35100...

Page 33: ...Zeta 450 7...

Page 34: ...NECTA VENDING SOLUTIONS SpA Sx35300...

Page 35: ...Zeta 750 9...

Page 36: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Page 37: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Page 38: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Page 39: ...smitted to third parties without the written permit of the Manufac turer who has the sole ownership Le fabricant se r serve le droit de modifier sans pr avis les caract ristiques des appareils pr sent...

Page 40: ......

Reviews: