background image

5 5

© by NECTA VENDING SOLUTIONS SpA

01 10 126-03

PROGRAMMING

The integrity of the vending machine and its conformity
with the rules and regulations in force for its relevant
systems must be checked by qualified personnel at least
once a year.
Maintenance operations should be carried out with the
machine energised and therefore exclusively by qualified
personnel, who are trained in the correct use of the machine
and aware of the specific risks of such condition.
To energise the electrical system of the machine with the door
open, simply insert the special key into the door switch.

The dispensing motors remain disconnected, thanks
to the special switch (see Fig. 5), even with the key
inserted.

This is to avoid the risk of accidental injury.

The rotors must be electrically operated with the door
closed.

Energised parts cannot be accessed with the door
open. Only those parts inside the machine with protec-
tive covers, and carrying the message "disconnect
electricity before removing the protective cover", re-
main energised.

Before removing such protective covers, the external
switch must be disconnected.

The door can be closed only after removing the key from the
door switch.

CONTROL BOARD FUNCTIONS
AND INDICATOR LIGHTS

The control board controls  all of the apparatus functions,
and more precisely:

- Serial interface for 24 V ac Executive electronic coin

mechanism.

- Parallel interface for 24 V dc coin validator

- Serial interface for MDB coin mechanism.

- Programming of the number of selections: 1 to 10.

- Programming of the vending price for each single

selection.

- Time-out function for the vending motors, adjustable

from 0 to 30 seconds.

- Programming of the coin values for use with 24 V

validator.

- Storing of the total sales for each selection.

- Storing of the total amount of all sales.

- Storing of the total coin value cashed.

- Storing of the motor locks following a time-out condi-

tion.

- Storing of the total motor resets.

- Storing of the number of serial transmission failures

occurred.

LED L1 is normally switched off; it blinks when no commu-
nication takes place with the coin mechanism.
LED L2 is switched on when 24 V dc voltage is detected.
LED L3  is switched on when  5 V dc voltage is detected.
Trimmer TR1 controls the contrast of the liquid crystal
display (available as optional).
Push-button P1 resets the control board.

Fig. 27

CN1

Executive serial interface

CN2

MDB serial interface

CN3

RS232 expansion

CN4

Not used

CN5

24 V validator interface

CN6

Not used

CN7

LED segment display

CN8

Provision for LCD

CN9

Input/output keypad 1 to 6

CN10

Input/output keypad 7 to 8

CN11

Input/output keypad 9 to 10

CN12

Empty state micro-switch, motor cam 1 to 7

CN13

Empty state micro-switch, motor cam 8

CN14

Empty state micro-switch, motor cam 9 to 10

CN15

Motor output 1 to 8

CN16

Motor output 9 to 10

CN17

Board power supply

CN18

Not used

CN19

MDB power supply

CN20

Not used

CN21

Not used

F1

Motor fuses

F2

24 Vac board power supply fuse

RL1 - 10

Motor relays

J9

Reset contacts

Summary of Contents for Zeta CB Series

Page 1: ...MANTENIMIENTO INSTALLATION BEDIENUNG WARTUNG HANDBOEK VOOR GEBRUIK INSTALLATIE ONDERHOUD IT Italiano Pagina 1 FR Fran ais Page 21 UK English Page 41 ES Espa ol P gina 61 DE Deutsch Seite 81 NL B Nede...

Page 2: ......

Page 3: ...a de identificaci n resulta conforme a las disposiciones legislativas de las directivas 89 392 89 336 73 23 CEE y modificaciones y integraciones sucesivas Declara que o distribuidor descrita na chapa...

Page 4: ......

Page 5: ...PAGE 4 POWER CONSUMPTION PAGE 4 VARIABLE COMBINATION LOCK PAGE 45 LOADING AND CLEANING PAGE 45 DOOR SWITCH PAGE 45 DISPENSING MODULES PAGE 45 CONTROLSAND INFORMATION PAGE 47 LOADING PAGE 47 RELEASING...

Page 6: ...hine Thereforeitmustalwaysfollowthemachine whenitis moved or ownership is transferred so that different operators may be able to consult it Beforeinstallingandusingthemachine itisfirstnecessary tocare...

Page 7: ...sons caused by incorrect installation Theintegrityofthevendingmachineanditsconformity with the rules and regulations in force for its relevant systems must be checked by qualified personnel at least o...

Page 8: ...l o v y l p p u S 0 3 2 0 3 2 0 3 2 z H y c n e u q e r f y l p p u S 0 5 0 5 0 5 W r e w o p d e l l a t s n I 0 5 7 0 5 7 0 0 8 V p m a l t r o h s r o o D 0 3 2 0 3 2 0 3 2 W p m a l t r o h s r o...

Page 9: ...icro switchdisconnects the power from the electrical system of the machine to allowtheloadingandroutinecleaningoperationsdescribed below in full safety All operations requiring the machine to be energ...

Page 10: ...o switch 5 Limit micro switch Fig 7 1 Double column 2 Single column 3 Rotor The columns can be preset for dispensing 66 dia cans or round bottles with a diameter range of 62 to 73 mm Warning glass bot...

Page 11: ...the chute inlet and let them roll down It is not important which side the top of the can is facing Should a product chute be completely empty for ex whenfirstinstallingthemachine afterloadingmakea sel...

Page 12: ...ATURE CONTROL Thethermostatisinitiallyadjustedsothatatemperatureof 1 5 Cismaintainedinthelowerportionoftherefrigerated box containing bottles and cans which will be sold first The thermostat is locate...

Page 13: ...outlet remove all products from the columns and clean the inside and all accessories INSTALLATION The machine installation and the following maintenance operations should be carried out with the machi...

Page 14: ...the power cable should be made by qualified and suitably trained personnel only using cables type HO5 RN F HO5 V V F or H07 RN F with a 3x1 5 mm2 section Do not use adapters multiple sockets and or e...

Page 15: ...s 2 65 66 67 mm thickness 3 68 69 70 mm thickness 4 Short adapting plate 5 Long adapting plate The rotor insert can be identified by the dispensed product diameter printed on the element To install or...

Page 16: ...LEMENTS The anti friction elements are frames made of special plastic material which facilitate product sliding For dispensing bottles the anti friction elements are fitted onthedoublecolumnbafflesand...

Page 17: ...mn back panel BOTTLE GUIDES FOR SINGLE COLUMNS The bottle guides have the function of keeping bottles with a tapered neck correctly aligned so that they do not tilt forward Forsinglecolumns theguidesa...

Page 18: ...hrough an opening with a width less than the smallest dimensionofthemachine thedoorandthedoorframecan be removed to temporarily reduce the depth to 750 mm The disassembly and reassembly operations mus...

Page 19: ...validator Serial interface for MDB coin mechanism Programming of the number of selections 1 to 10 Programming of the vending price for each single selection Time out function for the vending motors a...

Page 20: ...lection is blocked the corresponding button is illuminated Whenpressingtheilluminatedbutton thedisplayindicates if the cause of the blockage is an empty module and ifthecauseisaproblemconnectedwiththe...

Page 21: ...machine code 6th digit of machine code Time of cycle start Motor safety time 0 to 30 seconds Initialising Countersdisplay The setting sequence of the parameters varies according to the type of interfa...

Page 22: ...se minimum 1 maximum 10 columns then press button 2 to store the new data unit and go to the next parameter x is the number of selections It can be set to values varying from 1 to 10 default 6 Type of...

Page 23: ...e MDB only It is the value of the maximum amount of change returned If set to 0 the maximum possible value is returned Multiple sales MDB only This function is used to make available to the user any a...

Page 24: ...n 2 each time the illuminated button indicates the selection to which the value on the display is referred Toresetavaluepressbutton5 thedisplaywillberesetand the next data unit will automatically be d...

Page 25: ...BOARD SM CONTROL BOARD ST STARTER TERM THERMOSTAT TR TRANSFORMER TX DELAYED FUSE X COURRENT SIGLA DENOMINACION MEMORIA ESQUEMA ELECTRICO BDV CONNECTOR PARA MONEDERO BDV CF CONDENSADOR DEL FILTRO COM C...

Page 26: ...NECTA VENDING SOLUTIONS SpA Sx34002...

Page 27: ...Zeta 550 9...

Page 28: ...NECTA VENDING SOLUTIONS SpA Sx34400...

Page 29: ...Zeta 550 6...

Page 30: ...NECTA VENDING SOLUTIONS SpA Sx34700...

Page 31: ...Zeta 450 5...

Page 32: ...NECTA VENDING SOLUTIONS SpA Sx35100...

Page 33: ...Zeta 450 7...

Page 34: ...NECTA VENDING SOLUTIONS SpA Sx35300...

Page 35: ...Zeta 750 9...

Page 36: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Page 37: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Page 38: ...by NECTA VENDING SOLUTIONS SpA NOTE...

Page 39: ...smitted to third parties without the written permit of the Manufac turer who has the sole ownership Le fabricant se r serve le droit de modifier sans pr avis les caract ristiques des appareils pr sent...

Page 40: ......

Reviews: