CHAPTER 20 ELECTRICAL SPECIFICATIONS
User’s Manual
U15075EJ2V1UD
331
Data Retention Timing (STOP Mode Release by RESET)
V
DD
Data retention mode
STOP mode
HALT mode
Internal reset operation
Operation mode
t
SREL
t
WAIT
STOP instruction execution
V
DDDR
RESET
Data Retention Timing (Standby Release Signal: STOP Mode Release by Interrupt Request Signal)
V
DD
Data retention mode
STOP mode
HALT mode
Operation mode
t
SREL
t
WAIT
STOP instruction execution
V
DDDR
Standby release signal
(interrupt request)
Oscillation Stabilization Wait Time (T
A
= –40 to +85
°
C, V
DD
= 1.8 to 5.5 V)
Parameter Symbol
Conditions
MIN.
TYP.
MAX.
Unit
Crystal/ceramic
oscillation
2
15
/f
X
s
Release by RESET
RC oscillation
2
7
/f
CC
s
Crystal/ceramic
oscillation
Note 2
s
Oscillation stabilization
wait time
Note 1
t
WAIT
Release by interrupt
RC oscillation
2
7
/f
CC
s
Notes 1.
Use a resonator whose oscillation stabilizes within the oscillation stabilization wait time.
2.
Selection of 2
12
/f
X
, 2
15
/f
X
, or 2
17
/f
X
is possible with bits 0 to 2 (OSTS0 to OSTS2) of the oscillation
stabilization time selection register (OSTS).
Remarks 1.
f
X
: Main system clock oscillation frequency (crystal/ceramic oscillation)
2.
f
CC
: Main system clock oscillation frequency (RC oscillation)