68
Command line interface (CLI) (EM card)
The command-line interface (CLI) of EM cards enables you to configure and manage networks and
modules installed in the Blade Enclosure, such as CPU blades and switch modules.
You can use the CLI from the EM serial console or the EM console. For more information on the
CLI, the EM serial console, and the EM console, see the User‟s Guide of the Blade Enclosure.
Initial settings
Configure the initial settings of switch modules and pass-through cards installed in the Blade
Enclosure from the EM serial console or the EM console. For information on how to configure the
settings, see “Setting module access right for a user” and “Verifying, backing up, and restoring the
EM card configuration” in the User‟s Guide of the Blade Enclosure.
Setting the module access rights for a user (EM card)
1.
Check that the EM card is powered on.
2.
Check that you are logged on as “Administrator” or with the access rights of an
ADMINISTRATOR or OPERATOR from the CLI of the EM serial console or the EM console.
If you are not, log on as “Administrator” or with the access rights of an ADMINISTRATOR or
OPERATOR.
3.
Run the following command from the CLI. For details, see “Command specification” in the
User‟s Guide of the Blade Enclosure.
Setting rights to access modules (strongly recommended)
Configures the user‟s rights to access switch modules and pass through cards:
(Before you configure the settings, you should know the slot numbers of the target
modules for which you are configuring the settings.)
ASSIGN SWITCH [<slot number > | < slot number> - <slot number> | <slot number>, <
slot number > | ALL] <user name>
<slot number> and „-„(hyphen) or „,‟(comma) must be separated by a blank space.
4.
Run the following command from the CLI to confirm the settings are effective.
Use the on and off operations of the module ID
LED‟
s as a user who is granted the access
right. For details of the operations, see “Commands” in the User‟s Guide of the Blade
Enclosure.
On and off of module ID
LED‟
s
Switch on and off the ID
LED‟
s of the switch modules and pass through cards as a user
who is granted the access right.
(Before you perform switch-on and off, you should know the slot numbers of the target
modules.)
SET SWITCH UID <slot number> [ON | OFF]
Summary of Contents for SIGMABLADE N8406-017
Page 14: ...14 は ブレード収納ユニットのユーザーズガイドを参照してください ...
Page 16: ...16 ...
Page 18: ...18 ...
Page 22: ...22 ...
Page 32: ...32 以上で完了です ...
Page 35: ...35 Memo ...
Page 50: ...50 2006 日本電気株式会社の許可なく複製 改変などを行うことはできません ...
Page 51: ...51 保護用紙 ...
Page 54: ...54 damage arising from the use of this manual regardless of 4 above ...
Page 80: ...71 Memo ...
Page 93: ...84 This Page Intentionally Left Blank ...
Page 94: ...85 This Page Intentionally Left Blank ...
Page 95: ...86 855 900578 A0 F 456 01763 000 PN 456 01763 000 ...