63
Powering on and off
Powering on and off switch modules and pass-through
cards
Switch modules and pass-through cards installed in the Blade Enclosure can be powered on and off
in one of two ways. Power on connected peripheral equipment first and then power on the modules
and/or pass-through cards. For information on status or confirmation after switch modules and/or
pass-through cards are powered on, see “Checking operations” in “Command line interface (CLI)
(EM card).”
Powering on from the Blade Enclosure
When the Blade Enclosure is powered on by rack power-on, switch modules and pass-through
cards installed in the Blade Enclosure are automatically powered on. Replacement switch modules
and pass-through cards are also powered on automatically if the replacement is done with the Blade
Enclosure powered on. (For information on powering on the Blade Enclosure, see the User‟s Guide
of the Blade Enclosure.)
Powering on by using the command line interface (CLI) of the EM card
Switch modules and pass-through cards installed in the Blade Enclosure can be powered on and off
by using the command line interface (CLI) of the EM card.
This section describes how to power on and off a CPU blade by using the CLI. For information on
the CLI, see “Command-line interface (CLI) (EM card)” and “How to describe a command” in the
User‟s Guide of the Blade Enclosure. You can connect to the CLI either through a telnet connection
or through the serial port. For information on connecting to the CLI, see the User‟s Guide of the
Blade Enclosure.
Check
A user who powers on and/or off switch modules and pass-through cards by
using the CLI should be “Administrator” or have the access rights of an
ADMINISTRATOR or OPERATOR
Follow the instructions below to power on a switch module or pass-through card by using the CLI:
1.
Check that the EM card is powered on.
2.
Connect to the CLI of the EM card and log in as “Administrator” or with the access rights of an
ADMINISTRATOR or OPERATOR.
3.
Enter the following command. For details, see “Command specifications.”
Powering on:
Powers on the specified switch module or pass-through card:
POWERON SWITCH <
slot number
>
Summary of Contents for SIGMABLADE N8406-017
Page 14: ...14 は ブレード収納ユニットのユーザーズガイドを参照してください ...
Page 16: ...16 ...
Page 18: ...18 ...
Page 22: ...22 ...
Page 32: ...32 以上で完了です ...
Page 35: ...35 Memo ...
Page 50: ...50 2006 日本電気株式会社の許可なく複製 改変などを行うことはできません ...
Page 51: ...51 保護用紙 ...
Page 54: ...54 damage arising from the use of this manual regardless of 4 above ...
Page 80: ...71 Memo ...
Page 93: ...84 This Page Intentionally Left Blank ...
Page 94: ...85 This Page Intentionally Left Blank ...
Page 95: ...86 855 900578 A0 F 456 01763 000 PN 456 01763 000 ...