CHAPTER 5 USAGE EXAMPLE
User’s Manual U17307EJ2V0UM
54
(7) [Autoprocedure (EPV)] command execution
Select [Device]
→
[Autoprocedure (EPV)] from the menu bar.
When the [Autoprocedure (EPV)] command is executed, [Erase]
→
[Program] are executed sequentially for the
µ
PD78F9222. In this example, “Blank check before Erase” and “Checksum after Program” are checked. So,
blank check is performed before the execution of the [Autoprocedure (EPV)] command, and checksum is
performed after the execution of the [Autoprocedure (EPV)] command.
Figure 5-8. After EPV Execution
(8) Terminating the system
<1> If other devices need not be programmed, select [File]
→
[Quit] to terminate the GUI software.
All settings executed so far are saved in the FPL2.INI file, so that those settings can be reused when the
GUI software is restarted.
<2> Disconnect the target cable from the target system.
<3> Disconnect the USB cable from the FPL2.
(9) Restart
When the system is restarted, the same screen as shown in Figure 5-6 appears.
"...finish" is displayed.