CHAPTER 4 OPERATION USING GUI SOFTWARE
User’s Manual U17307EJ2V0UM
39
While programming is in progress, the progress is displayed in the action log window, indicating the operation
of the programmer. This progress indicates the progress of programming the target device as a percentage.
After completing the [Program] command, the GUI software displays the target device command execution
result.
(4) [Verify] command
This command is not supported.
(5) [Security] command
The [Security] command initiates the programming of the security flag of the target device connected to the
FPL2. Set ‘Security flag settings’ on the Advance tab of the [Device] > [Setup…] menu.
(6) [CheckSum] command
The [CheckSum] command initiates the displaying and verifying of the checksum values of the target device
connected to the FPL2 and the user program. "OK” is displayed if the values match, and “ERROR: checksum
does not match” if the values do not match.
(7) [Autoprocedure (EPV)] menu
The [Autoprocedure (EPV)] command sequentially executes the [Erase] and [Program] commands
explained above.
After execution of the [Autoprocedure (EPV)] command, to verify the checksum values of the data written to the
flash memory of the target device and the program file to detect a communication error of the user program
while it is being transmitted, specify automatic execution of the [CheckSum] command after execution of the
[Program] command, using the Command options on the Advance tab of the [Device] > [Setup…] menu.
During EPV, the progress status of the programmer operation is displayed in the action log window. Refer to
CHAPTER 5 USAGE EXAMPLE
for the selected command, and its execution operation and message.
After completing the [Autoprocedure (EPV)] command, the GUI software displays the target device command
execution result.
(8) [Signature read] command
This command is not supported.
(9) [Setup…] command
The [Setup…] command is used to perform flash memory writing settings in accordance with the
user environment, and command option settings. Each time the GUI software is started, the
parameter file (.PRM) and customized setup file (.SET) that were used last are read, and their setting contents
are displayed. Settings can be changed in accordance with the user environment, except for the parameters
that are dimmed. In addition, new settings can be saved to the customized setup file (the data of the
parameter file cannot be changed).
(a) Standard setup
This menu is used to set the rewriting environment of the target device’s flash memory.
The mode of communication with the target device and the operating clock of the device differ depending
on the device used. Refer to the manual of the device used for details.