CHAPTER 2 HARDWARE INSTALLATION
User’s Manual U17307EJ2V0UM
15
Figure 2-5. Connecting Target Cable with FPL2-FA
<2> Make sure that the power to the target system is not turned on.
Caution Make sure that the power to the target system is not turned on before connecting
the target cable. If the target cable is connected after the power to the target system
is turned on, the FPL2 may be damaged.
<3> Connect the FP4 connector with the connector installed in the target system.
Caution When the MODE switch is set to 3 V (power is supplied from the FPL2), V
DD
is always
output from the FP4 connector. Be sure to remove the FP4 connector before
inserting or removing a device in the target system.
<4> Be sure to turn on the power to the target system.
(When the MODE switch is set to 3 V, power is supplied from the FPL2, so this step is not required.)
(b) When the FPL2 is connected with the target system without using the FPL2-FA
<1> Disconnect the FPL2-FA from the target cable.
<2> Make sure that the power to the target system is not turned on.
Caution Make sure that the power to the target system is not turned on before connecting
the target cable. If the target cable is connected after the power to the target system
is turned on, the FPL2 may be damaged.
<3> Connect the tip of the target cable marked "0.GND" to GND of the target system.
Caution Be sure to connect "0.GND" at the beginning. If connections are made in an
incorrect order, the FPL2 and target system may be damaged.
<4> Make sure that the power to the target system is not turned on.
0.
GND
Match the number.
Tip of target cable