NDA-24305
CHAPTER 5
Page 131
Revision 1.0
PRI TRUNK TO TIE LINE CONNECTION WITH PAD CONTROL
P-39
PRI TRUNK TO TIE LINE CONNECTION WITH PAD CONTROL
1. General Description
This feature provides a switchable transmission pad for PRI trunks, which allows tandem connections.
Necessary PAD CONTROL is activated to protect against echo.
2. Operating Procedure
No manual operation is required.
3. Programming
STEP 1:
APAD - Assign the Pad data required for the Tandem connection. Assign the following:
KIND:
T (Tandem Connection) or S (Station)
ICRT:
Incoming Route Number
OGRT: Outgoing
Route
Number
SFC: Service
Feature
Class
IC PAD:
Incoming PAD Data (1-15)
OG PAD: Outgoing PAD Data (1-15)
RT: Route
Number
PAD DATA:
Note
Note:
See “Circuit Card Manual”.