1. Installing Internal Optional Devices
Express5800/T120e User’s Guide
150
Chapter 2 Preparations
When the message as shown below appears, application of SDR data completes.
-------------------------------------
CFG Identify : ncfg1000
Check the value.
SDR Revision :
SDR Version
00.09
Check the value.
-------------------------------------
Remove the media, Press any key to Reboot
Confirm that "CFG Identify" and "SDR Revision" of the installed/replaced power supply unit and HDD cage
are indicated as shown below.
Model number of server
HDD cage
CFG Identify
SDR Revision
N8154-43F ncfg5000
One N8154-44F
ncfg5010
Tow N8154-44F
ncfg5020
One N8154-42F
ncfg5011
Tow N8154-42F
ncfg5021
N8100-2089F
Three N8154-42F
ncfg5031
N8154-43F ncfg5100
One N8154-44F
ncfg5110
Tow N8154-44F
ncfg5120
One N8154-42F
ncfg5111
Tow N8154-42F
ncfg5121
N8100-2090F
N8100-2091F
Three N8154-42F
ncfg5131
SDR Version
xx.xx
* "xx.xx" of SDR Revision represents the revision number indicated on "SDR UPDATE
TOOL(243-423836-504)" media provided with the server.
If the applied SDR data differs from system configuration, power off the server, disconnect power cord,
and confirm jumper switch settings for power configuration and fan unit configuration.
Also make sure that SGPIO cable is properly connected if 2.5-inch or 3.5-inch HDD cage is installed in
the server.
If jumper setting and/or cable connection is improper, correct them, and apply SDR data again.
If no incorrectness was found, contact your sales representative.
Remove the CD-ROM "SDR UPDATE TOOL (243-423836-504)" from optical disk drive of the server.
Press any key on keyboard to restart the server.
Press the <F4> key while POST is running to launch ROM Utility.
Clear System Event Log (SEL) by selecting menus in the order as shown below.
Keyboard Type Select
Maintenance Utility
IPMI Information Viewer
Clear the System Event Log (SEL) Repository
Enter
Enter
Now the System Event Log (SEL) is cleared.
Press the <ESC> key to return to
Off-line TOOL MENU
, and select
Exit
. The server restarts.