1. Installing Internal Optional Devices
Express5800/T120e User’s Guide
111
Chapter 2 Preparations
1.17
Fan Unit
The server can contain non-redundant fan unit or hot-swap redundant fan unit.
With redundant fan unit, the server can continue operation even one of the fan unit fails.
Note
It is recommended to install fan unit after installing other optional devices except
for hot-plug hard disk drive.
1.17.1 Installing non-redundant fan unit
Install fan unit in the following procedure.
1.
Refer to steps 1 to 7 in
Chapter 2
1.3 Overview of Installation and Removal
) for preparations.
2.
Secure the rear fan (120 mm sq.) to the chassis using four screws provided with non-redundant fan unit,
and connect the fan cable to FAN2 connector on motherboard.
3.
Connect two cables for front fan unit (92 mm sq.) to motherboard.
Connect a cable for fan unit in FAN1 with FAN1 connector on motherboard.
Connect a cable for fan unit in FAN4 with FAN4 connector on motherboard.
Connect a cable for fan unit in FAN3 with FAN3 connector on motherboard.
See the figure below.
Note
After the front fan is installed, it is difficult to connect a fan cable to motherboard.
Thus, first connect fan cable to motherboard, then install the front fan.