English-53
English
Mail Setting
Click on “MAIL” on the left column below HOME.
This option notifi es your computer about an error message via e-mail when using wired LAN. An error message will be sent
when an error occurs in the monitor.
ALERT MAIL
Selecting [ENABLE] will turn on the Alert Mail feature.
Selecting [DISABLE] will turn off the Alert Mail feature.
STATUS MESSAGE
Selecting [ENABLE] will turn on the STATUS MESSAGE feature.
Selecting [DISABLE] will turn off the STATUS MESSAGE feature.
SENDER’S ADDRESS
Type in the sender’s address. Up to 60 alphanumeric and symbols characters can be used.
SMTP SERVER
Type in the SMTP server name to be connected with the monitor.
Up to 60 alphanumeric characters can be used.
RECIPIENT’S
ADDRESS 1 TO 3
Type in your recipient’s address. Up to 60 alphanumeric and symbols characters can be used.
AUTHENTICATION
METHOD
This selects the authentication method of the email transmission.
POP3 SERVER
This specifi es the address of the POP3 server that is used in the authentication of the email.
USER NAME
This sets the user name for logging into the authentication server when authentication is required
for the email transmission. Up to 60 alphanumeric characters can be used.
PASSWORD
This sets the password for logging into the authentication server when authentication is required for
the email transmission. Up to 60 alphanumeric characters can be used.
TEST MAIL
Click on this button to send a test email to check if your settings are correct.
NOTE:
• If you execute a test, you may not receive an Alert email.
Should this happen, check whether the network settings are correct.
• If you entered an incorrect address in a test, you may not receive an Alert email.
Should this happen, check whether the Recipient’s Address is correct.
HINT:
For the control command diagram, please see the fi le “External_Control.pdf” on the CD-ROM supplied with this
monitor.
Alert error message list
Error number
* ErrorCode
Alert mail Message
Explanation
Measure
70h ~ 7Fh
The monitor’s power supply is not
functioning normally.
Standby power abnormal
Please contact your supplier.
80h ~ Fh
The cooling fan has stopped.
Cooling fan abnormal
Please contact your supplier.
90h ~ 9Fh
The monitor’s backlight unit is not
functioning normally.
Backlight abnormal
Please contact your supplier.
A0h ~ AFh
The monitor is overheated.
Temperature abnormal
Please contact your supplier.
A2h
A Sensor reached the temperature limit
which was specifi ed in the OSD.
*Condition: DISPLAY PROTECTION-FAN
CONTROL-COOLING FAN = AUTO
Reconfi rm the settings in the OSD
(DISPLAY PROTECTION-FAN
CONTROL) or please contact your
supplier.
B0h ~ BFh
The monitor does not receive an input
signal.
No signal
Please check “No picture” in
“Troubleshooting”.
D0h
The remaining capacity of the error log
decreased.
The Proof of Play log memory size is
1 more hour.
Please get a log by using PD external
command. See page 55.
D1h
The battery for clocks is empty.
The battery is empty.
Please connect the monitor to the
power then recharge the battery.
Please set (DATE & TIME) in OSD.
E0h ~ EFh
A system error occurred in the monitor.
System error.
Please contact your supplier.