Troubleshooting

No picture

The signal cable should be completely connected to the display card/computer.

The display card should be completely seated in its slot.

Power Switch and computer power switch should be in the ON position.

Check to make sure that a supported mode has been selected on the display card or system being used.
(Please consult display card or system manual to change graphics mode.)

Check the monitor and your display card with respect to compatibility and recommended settings.

Check the signal cable connector for bent or pushed-in pins.

Check the signal input, “DVI-D”, “DVI-I” or “D-SUB” (only for MD212MC).

Power switch does not respond

Unplug the power cord of the monitor from the AC outlet to turn off and reset the monitor.

Image Persistence

Image persistence is when a residual or “ghost” image of a previous image remains visible on the screen. Unlike CRT
monitors, LCD monitors’ image persistence is not permanent, but constant images being displayed for a long period of
time should be avoided. To alleviate image persistence, turn off the monitor for as long as the previous image was
displayed. For example, if an image was on the monitor for one hour and a residual image remains, the monitor should
be turned off for one hour to erase the image.

NOTE:

As with all personal display devices, NEC DISPLAY SOLUTIONS recommends using a moving screen saver at
regular intervals whenever the screen is idle or turning off the monitor when not in use.

Message “OUT OF RANGE” is displayed (screen is either blank or shows rough images only)

Image is displayed only roughly (pixels are missing) and OSD warning “OUT OF RANGE” is displayed: Either signal
clock or resolution is too high. Choose one of the supported modes.

OSD warning “OUT OF RANGE” is displayed on a blank screen: Signal frequency is out of range. Choose one of the
supported modes.

Image is unstable, unfocused or swimming is apparent

Signal cable should be completely attached to the computer.

Use the OSD Image Adjust controls to focus and adjust display by increasing or decreasing the FINE adjustment.
When the display mode is changed, the OSD Image Adjust settings may need to be readjusted.

Check the monitor and your display card with respect to compatibility and recommended signal timings.

If your text is garbled, change the video mode to non-interlaced and use 60Hz refresh rate.

LED on monitor is not lit (

no green or amber color can be seen)

Power Switch should be in the ON position and power cord should be connected.

Display image is not sized properly

Use the OSD Image Adjust controls to increase or decrease the Coarse adjustment.

Check to make sure that a supported mode has been selected on the display card or system being used.
(Please consult display card or system manual to change graphics mode.)

No Video

If no video is present on the screen, turn the Power switch off and on again.

Make certain the computer is not in a power-saving mode (touch the keyboard or mouse).

Self Diagnosis

The LCD display is equipped with the ability to self diagnose abnormalities. When the LCD detects a problem,
the LED on the back flashes in a pattern of long and short blinks, depending on the type of problem detected.

If the LED indicates a problem, please refer service to qualified personnel.

Summary of Contents for MD213MC - MultiSync - 21.3" LCD Monitor

Page 1: ...MD212MC MD213MC MD213MG INSTALLATION MAINTENANCE GUIDE...

Page 2: ...ions Ltd in Austria Benelux Denmark France Germany Italy Norway Spain Sweden U K All other brands and product names are trademarks or registered trademarks of their respective owners This symbol warns...

Page 3: ...atient environment and IEC 60601 1 certified equipment inside the patient environment Equipment connected to the analog or digital interfaces must comply with the respective IEC standards e g IEC 6095...

Page 4: ...a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try t...

Page 5: ...let and refer servicing to qualified service personnel under the following conditions When the power supply cord or plug is damaged If liquid has been spilled or objects have fallen into the monitor I...

Page 6: ...wered on This feature can be turned on or off in the Advanced OSD In case you find such bright Brand Logo annoying in your reading room environment you may easily switch this off By keeping the EXIT b...

Page 7: ...DVI D to DVI D cable 1 Quick Reference Guide CD ROM x 2 Cable Cover Power Cord Type of power cord included will depend on the where the LCD monitor is to be shipped Quick Reference Guide DVI D to DVI...

Page 8: ...mode Refer to the Screen rotation section in this manual 4 Place hands on each side of the monitor to tilt the LCD panel to a 30 angle and lift up to the highest position Figure C 1 5 Connect all cab...

Page 9: ...0 Turn on the monitor with power switch on the top Portrait or left side Landscape of the monitor Figure E 1 Turn on the computer NOTE DO NOT switch on off repeatedly 11 No touch auto adjust automatic...

Page 10: ...f the monitor and lift up to the highest position Figure RL 1 To rotate screen place hands on each side of the monitor screen and turn clockwise from Landscape to Portrait or counter clockwise from Po...

Page 11: ...the flexible arm for detailed instructions To fulfill the safety requirements the monitor must be mounted to an arm which guaranties the necessary stability under consideration of the weight of the m...

Page 12: ...tton for at least 3 seconds to display the visual inspection grayscale drawing and check the display performance Enters the OSD Control menu Enters OSD sub menus Changes the input source when not in t...

Page 13: ...SIZE H SIZE Analog input only Adjust the horizontal size by increasing or decreasing this setting If the AUTO Adjust function do not give you a satisfactory picture setting a further tuning can be per...

Page 14: ...LUE BASE Color temperature setting for Blue Base x ray film simulation NOTE To reset a poor image setting turn on the monitor by using the power switch on the top in portrait mode or left side in land...

Page 15: ...eset choices are 10 120 seconds by 5 second increments OSD LOCK OUT This control completely locks out access to all OSD control functions When attempting to activate OSD controls while in the Lock Out...

Page 16: ...lution other than the optimized resolution is used After power is turned on or when there is a change of input signal or the video signal doesn t have proper resolution the Resolution Notifier window...

Page 17: ...he blue component of the image Press Left or Right to adjust Analog input only R FINE Adjusts the FINE setting of the RED component of the image Analog input only Press Left or Right to adjust G FINE...

Page 18: ...ot clock For this a Moir test pattern could be used This function may alter the width of the picture Use left Right Menu to center the image on the screen If the V Size H Size is wrongly calibrated th...

Page 19: ...ted when CUSTOM is selected PRIORITY only for MD212MC MD213MC Sets gamma characteristics for optimum viewing of contrast or color GRAYSCALE Optimizes gamma for contrast COLOR Optimizes gamma for color...

Page 20: ...nput signal is lost STANDARD Monitor enters power save mode automatically when the input signal is lost Response Improve Turns the RESPONSE IMPROVE function on or off Response Improve may reduce blurr...

Page 21: ...in the corner of the screen Signal information is either On Off Resolution Notifier The optimal resolution is 1200 x 1600 in portrait mode or 1600 x 1200 in landscape mode for MD212MC and 1536 x 2048...

Page 22: ...ker than normal or have color distortion Use of the Clamp position control will adjust images to their normal state TagA CALIBRATION Selects the Calibration mode page 21 SELF TEST MODE Displays an all...

Page 23: ...ontamination DO NOT press the calibrator against the display panel KEY MAP UP DOWN Changes from setting to setting LEFT RIGHT Changes the setting selection ie SELF or COPY SELECT Moves to the next ste...

Page 24: ...y A must display a white screen Enter the Advanced OSD by pressing RESET and EXIT Use LEFT and RIGHT keys to move into Tag A and select SELF TEST MODE 2 Select COPY in the Mode selection in Display B...

Page 25: ...UNING MODE 1 1 MD213MG does not have FINE TUNING MODE 10 At the FINE TUNING MODE message Figure 13 press SELECT if the calibration is satisfactory If the calibration is unsatisfactory there are two op...

Page 26: ...17 3 Select the Color setting in COLOR 2 selection and Gamma setting in GAMMA selection 2 MD213MG does not have COLOR selection 4 Press SELECT to start the DICOM MEASUREMENT This may take several min...

Page 27: ...o 75 Hz NEC DISPLAY SOLUTIONS cites 1440 x 900 1 at 60 Hz to 75 Hz recommended resolution for optimal 1600 x 1200 1 at 60 Hz display performance Active Landscape Horiz 432 mm 17 0 inches Vert 324 mm 1...

Page 28: ...x 1200 1 at 60 Hz Analog 1920 x 1200 1 at 60 Hz Digital NEC DISPLAY SOLUTIONS cites 2048 x 1536 1 at 35 Hz recommended resolution for optimal 2048 x 1536 at 60 Hz Digital display performance Active La...

Page 29: ...at 75Hz 1280 x 960 1 at 60 Hz 1280 x 1024 1 at 60 Hz to 85 Hz 1600 x 1200 1 at 60 Hz 1920 x 1200 1 at 60 Hz Analog 1920 x 1200 1 at 60 Hz Digital NEC DISPLAY SOLUTIONS cites 2048 x 1536 1 at 35 Hz rec...

Page 30: ...djust the colors on your screen and customise the color accuracy of your monitor to a variety of standards OSD On Screen Display Controls Allow you to quickly and easily adjust all elements of your sc...

Page 31: ...or shows rough images only Image is displayed only roughly pixels are missing and OSD warning OUT OF RANGE is displayed Either signal clock or resolution is too high Choose one of the supported modes...

Page 32: ...in Japan or http www necdisplay com in USA Energy Saving This monitor features an advanced energy saving capability When a VESA Display Power Management Signalling DPMS Standard signal is sent to the...