3.
Troubleshooting Functional Failures in Operation
30
3.4.3
Actions against Troubles on 10BASE-T/100BASE-TX/
1000BASE-T
If a trouble occurs on 10BASE-T/100BASE-TX/1000BASE-T, follow the procedure below to isolate the problem.
1. Checking log
For the log, see the manual "Message Log Reference."
2. Isolating the problem according to the failure analysis method
Isolate the problem according to the failure analysis method listed below.
5
fault
Unavailable configuration has been set.
Use configuration command
fldm prefer
to
correctly set flow distribution pattern of the filter
and QoS function.
6
Use configuration command
fwdm prefer
to
correctly set the distribution pattern of the
maximum number of entries per device.
7
The BSU/PSP is faulty.
According to the log of the BSU displayed by the
show logging
command, see the corresponding
part in manual "Message Log Reference" and
follow [Action] described.
8
inactive
[IP8800/S6700]
The
inactivate bsu
command is set.
Use the
activate bsu
command to make the
BSU active, standby hot, or standby cold status. If
it does not become standby hot or standby cold
status, see "
3.20 Problems on Redundant
Configuration of Basic Switching Unit (BSU)
[IP8800/S6700]
."
9
The BSU is not fully inserted.
Install the BSU board correctly.
10
Different type of BSUs are installed together.
Unify the type of all BSU boards.
11
BSU not supported by the software version is
installed.
Check the BSU board type and software version.
Replace the BSU board or update the software.
12
BSU not supported by this device is installed.
Replace the BSU board.
13
notconnect
[IP8800/S6700]
The BSU is not installed.
Check if as many BSU boards as required for active
BSU + standby BSU (if standby BSU is not
required, only active BSU) are installed. If so, no
action is required. If not so, install the required
number of BSU boards.
14
initialize
The BSU/PSP is being initialized.
Wait until initialization completes.
15
disable
[IP8800/S6700]
no power enable
is set by configuration
command.
After checking that the BSU board to be used is
installed, use configuration command
power
enable
to make the BSU active, standby hot, or
standby cold status. If it does not become standby
hot or standby cold status, see "
3.20 Problems on
Redundant Configuration of Basic Switching Unit
(BSU)
[IP8800/S6700]
."
No.
BSU Operation
Status
Problem
Action