3.
Troubleshooting Functional Failures in Operation
114
Figure 3-23: Display Example of Configuration 3
(config)# show interfaces
interface gigabitethernet 1/2
switchport mode access
sflow forward ingress
<-
sflow forward
must be set here.
!
(config)#
• See "
3.23.1 Checking Filtering/QoS Setting Information
" to confirm that "filter" is not set for the physical
port subject to flow statistics.
• Specifying Source IP address for sFlow packets with "sflow source," check to see if the IP address is
assigned to the port of this system.
Figure 3-24: Display Example of Configuration 4
(config)# show sflow
sflow destination 192.1.1.1 6455
sflow sample 2048
sflow source 192.1.1.100
<-
This IP address must be one assigned to the port of
this system.
!
(config)#
(4) Checking NIF/port status
Execute the
show interfaces
command to check that up/down status of the physical port of this system or the
physical port connecting to the collector to be monitored by sFlow statistics is "active" (normal operation).
Figure 3-25: Display Example of Port Status
> show interfaces gigabitethernet 1/5
Date 2006/10/24 17:19:34 UTC
NIF1: active 48-port 10BASE-T/100BASE-TX/1000BASE-T retry:0
Average:150Mbps/24Gbps Peak:200Mbps at 15:44:37
Port5: active up 100BASE-TX full(auto) 0012.e220.ec31
Time-since-last-status-change:1:47:47
Bandwidth:10000kbps Average out:5Mbps Average in:5Mbps
Peak out:5Mbps at 15:44:36 Peak in:5Mbps at 15:44:18
Output rate: 4893.5kbps 16.8kpps
Input rate: 4893.5kbps 16.8kpps
Flow control send :off
Flow control receive:off
TPID:8100
:
>
Note: Confirm that "active" or "active up" is displayed at the underlined part.
If the port status is DOWN, see "
3.6.1 Communication Is Disabled or Is Disconnected
" and "
3.9.1 Communication Is
Disabled or Is Disconnected
."
(5) Checking settings of collector
•
Confirm that the UDP port number (default: 6343) on the collector side is available to receive packets.
If the port is not ready for receiving packets, ICMP ([Type]Destination Unreachable [Code]Port Unreachable) will
be transmitted to this system.
•
Confirm that other settings on the collector used are correct.
Summary of Contents for IP8800/S2400 Series
Page 10: ......
Page 26: ......
Page 62: ......
Page 72: ......
Page 190: ......
Page 198: ......
Page 215: ...153 6 Line Test 6 1 Testing Line ...
Page 220: ......
Page 227: ...165 Appendix Appendix A Contents of show tech support Command Display ...
Page 248: ......