93
CHAPTER 9 SETTING NETWORK INFORMATION
<Example of setting>
Here is a setting example:
IP address = 12XXXXXXh
Port No.
= XXX4h
Both the IP address and port No. are set in hexadecimal number.
Turn ON power while holding down SW1
with IE-ETHER cable connected to CH3.
Press SW3 once.
Press SW3 and display 1 on LED2.
Press SW1 once.
Press SW2 once
Press SW3 and increment indication on LED2 to 2.
Press SW1 once.
Press SW1 once.
Hold down SW1 for 2 seconds or longer.
Displays current data
value after blinking.
Data is incremented to D.
Displays data to be set.
Blinks once (data is stored
to buffer).
Pointer is incremented.
Displays data to be set.
Blinks once (data is stored
to buffer).
All data has been completely
written to buffer.
Blinks two times and then extinguishes
(buffer contents are written to EEPROM).
These operations are repeated to store the data to be set to the buffer sequentially.
The stored data can be checked by pressing SW2 successively.