1. System BIOS
Express5800/R120e-1M, R120e-2M Maintenance Guide
85
Chapter 2 Convenient Features
(2) Power Control Configuration submenu
From the
Server
menu, move the cursor to
Power Control Configuration
and then press the <Enter> key to
show its submenus.
For details about the options, see the table below.
Option Parameter
Descriptions
AC-LINK
Stay Off
[Last State]
Power On
Specify AC link feature. Specify how the DC power
state should be when the AC power is supplied again
after loss of power. (See the table below)
Power ON Delay Time Mode
[Manually Setting]
Random
Select a method to specify the delay time before
powering on DC power. Available options are:
"User-specified value" or "random value".
This option is selectable when
Power On
or
Last
State
is specified in
AC-LINK
.
Delay Time
[45]-600
Specify the delay time within the range between
"xx"
and 600 seconds. The minimum configurable time is
displayed when executing
Load Setup Defaults
.
This menu appears when
Manually Setting
is
specified for
Power ON Delay Time Mode
.
Standby Power Save
[Disabled]
Enabled
Enable or disable the feature that saves the standby
power on standby. If this option is set to
Enabled
, the
AC-LINK
setting is fixed to
Power On
automatically
and cannot be changed. With AC power off state,
management, monitoring, and power-on of server are
disabled on remote site. Powering on the server is
available only by pressing the POWER switch on the
server.
If AC-LINK setting is changed from the remote site with
this option being set, you need to press the POWER
switch twice to power on the server.
Cold Redundant Mode
[Disabled]
Enabled
Enable or disable Cold Redundancy feature.
For details, refer to user's guide.
R120e-1M:Chapter 2 (1.19.1 Cold Redundant Feature)
R120e-2M:Chapter 2 (1.27.1 Cold Redundant Feature)
[ ]: Factory setting