ftSMC Component Properties
3-18
Express5800/320Ma: Technical Reference Guide
PlexEpochValid
Specifies the maximum number of minutes you can keep a disk out
of the system without causing a full resynchronization when the disk
is returned to the system. A value of 0 disables any
resynchronization of the disk after a disk is removed from and
returned to the system. Default: 15 minutes.
PnpClass
Type of function as reported by Plug and Play.
PnpDescription
Description as it appears in Device Manager.
PnpDeviceID
Plug and Play device ID, including the Instance ID.
PnpDeviceLocation
Location of the function as reported by Plug and Play.
PnpManufacturer
Manufacturer of the function as reported by Plug and Play.
Polling Interval
The interval, specified in number of seconds, that the gateway VTM
waits between polling slave machines in the ftGateway group.
Polling determines if a slave is online or offline. The default value is
1800 seconds (30 minutes).
PollInterval
The interval, specified in number of seconds, at which the SES
driver monitors the storage enclosure for device faults and removals
by polling the SES device. The default poll interval is 3 seconds, and
the valid range is 1 to 10 seconds. Do not change the default value.
PositiveGoingHysteris
A value subtracted from a reading to determine if a threshold event
has cleared. A value of 0 means that the event clears once the
reading rises to one more than Low Warning or Critical Threshold.
PowerState
Indicates whether power is applied to the modem slot.
PPP Password
Password used to authenticate the system to the ASN when the
system calls home or when a call back is made to the system. See
the Express5800/320Ma ActiveService Network Configuration
Guide.
Preserve Alarm
Whether or not to preserve alarms after they are transmitted. False
(do not preserve) by default. See
Alarm Directory
in this table.
PreTimeoutInterrupt
If enabled, BMC generates the selected interrupt a fixed interval
before the watchdog timer expires. This property can take a value of
NMI, SMI, MessagingInterrupt, or None.
PreTimeoutInterval
The number of seconds that the PreTimeoutInterrupt is issued
before the timer expires.
Processing Rate
Sets the speed at which the Policy Service processes received
events. This property can take a value of Normal, Low, or Very Low.
Table 3-1. ftSMC System Inventory Component Properties (Continued)
Property
Description
Summary of Contents for Express5800/320Ma
Page 1: ...NEC Solutions America Inc NR550 Express5800 320Ma Technical Reference Guide...
Page 10: ...Preface x Express5800 320Ma Technical Reference Guide...
Page 24: ...ASN Connection Retry Cycle 2 10 Express5800 320Ma Technical Reference Guide...
Page 52: ...ftSMC Component Actions 3 28 Express5800 320Ma Technical Reference Guide...