ftSMC Component Properties
ftSMC Component Properties and Actions
3-19
PwrDownBrokenCpuEnabled
When a CPU element transitions to the Broken state, the system
powers it down if this property is enabled (True). The default is
enabled (True).
PwrDownBrokenIoEnabled
When an I/O element transitions to the Broken state, the system
powers it down if this property is enabled (True). The default is
enabled (True).
RdrLunLoadBalancing
Load balancing policy for this virtual disk. Default is On (enabled).
ReadingTime
For storage enclosures equipped with environmental sensors. The
date and time when the current reading from a storage enclosure
sensor was taken.
ReceiveMessageQueueInterr
uptEnabled
Enables (True) or disables (False) the receive message queue
interrupt.
RegistryPath
Location in the HKEY_LOCAL_MACHINE Registry key.
RevisionID
Chipset revision incremented when vendor updates chipset.
SELTime
The time used by the system event log. This value is set by the
Synchronize SEL date and time with System
action, which is
described in
Table 3-2
.
Send Alarms By
Defines whether call-home alarms will be sent by VTM adapter only,
the Internet only, VTM adapter with Internet backup, or the Internet
with VTM adapter backup.
Serial Number
The system serial number as stored in the system ID PROM. Filled
in automatically.
Short Idle Re-send Count
The number of re-send attempts, separated by
Short Idle Time
Between Re-sends
, that ftServer Manager will make before moving
to the medium idle interval.
Short Idle Time Between
Re-sends
The short Idle time, in seconds, between attempts to re-send an
alarm. After an unsuccessful attempt to send an alarm message,
ftServer Manager waits this long before it attempts to re-send the
alarm. After a number of unsuccessful attempts, defined by
Short
Idle Re-send Count
, ftServer Manager will wait the amount of time
defined by
Medium Idle Time Between Re-sends
before attempting
to re-send the alarm message
Site Heartbeat Granularity
The granularity of the site heartbeat interval. 0 = days, 1 = minutes.
Site Heartbeat Interval
The interval between site heartbeat alarms. Minimum interval =
10 minutes; maximum = 1 year; 0 = disabled.
Table 3-1. ftSMC System Inventory Component Properties (Continued)
Property
Description
Summary of Contents for Express5800/320Ma
Page 1: ...NEC Solutions America Inc NR550 Express5800 320Ma Technical Reference Guide...
Page 10: ...Preface x Express5800 320Ma Technical Reference Guide...
Page 24: ...ASN Connection Retry Cycle 2 10 Express5800 320Ma Technical Reference Guide...
Page 52: ...ftSMC Component Actions 3 28 Express5800 320Ma Technical Reference Guide...