![background image](http://html.mh-extra.com/html/nec/express5800-140hb/express5800-140hb_service-manual_251224191.webp)
Problem Solving 5-15
Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message
Description
Action
0B28
Unsupported CPU
detect on CPU slot 1
0B29
Unsupported CPU
detect on CPU slot 2
0B2A
Unsupported CPU
detect on CPU slot 3
0B2B
Unsupported CPU
detect on CPU slot 4
Unsupported CPU (old version) is
mounted in CPU slot.
Contact your service representative to
replace the failed CPU (number).
0B24
Invalid System
Hardware
Configuration
System hardware configuration
unmatched.
Contact your service representative.
0B30
|
0B35
Fan Alarm 1 – 6
occurred.
Fan error
Contact your service representative to
replace the faulty fan indicated in the system
event log.
0B40
Invalid System
Configuration Data
System configuration data is
damaged.
0B41
System
Configuration Data
Read Error
System configuration data read
failed.
Start the SETUP utility, execute [Advanced]
→
[Advanced]
→
[Reset Configuration Data],
then restart the system. If the error persists,
contact your service representative to
replace the I/O riser board or system I/O
board.
0B42
Resource Conflict
The PCI board resource is not
properly mapped.
Start the SETUP utility, execute [Advanced]
→
[Advanced]
→
[Reset Configuration
Data].
Set I/O addresses and IRQs in [Advanced]
→
[Peripheral Configuration] again. If the
error persists, contact your service
representative to replace the riser card or
system I/O board.
0B43
Warning: IRQ not
configured
The PCI board interrupt is not
properly set.
Start the SETUP utility, set the values in
[Advanced]
→
[PCI Device] again and
restart the server. If the error persists,
contact your service representative to
replace the riser card or system I/O board.
0B44
Expansion Rom not
initialized
The expansion ROM on the PCI
board is not initialized.
Check the PCI board installation. Or,
disable the PCI board setting not needed at
start-up in [Advanced]
→
[Option ROM] of
the SETUP utility.
If the error persists, contact your service
representative to replace the riser card or
system I/O board.
0B45
System
Configuration Data
Write Error
Write error on the data configuring
the system.
Start the SETUP utility, execute [Advanced]
→
[Advanced]
→
[Reset Configuration
Data].
If the error persists, contact your service
representative to replace the riser card or
system I/O board.
Summary of Contents for Express5800/140Hb
Page 1: ... S e r v i c e G u i d e EXPRESS5800 140Hb ...
Page 2: ......
Page 3: ... S e r v i c e G u i d e EXPRESS5800 140Hb ...
Page 10: ...viii Contents ...
Page 18: ...xvi Using This Guide ...
Page 48: ...1 30 System Overview ...
Page 64: ...2 16 Setting Up the System Figure 2 10 Connecting the AC Power Cord to the Server ...
Page 98: ...3 28 Configuring Your System ...
Page 101: ......
Page 176: ...4 76 Disassembly and Reassembly ...
Page 200: ...5 24 Problem Solving ...
Page 201: ...6 Illustrated Parts Breakdown Exploded View Field Replaceable Units ...
Page 211: ...A Technical Specifications Server Unit ...
Page 214: ...A 4 Technical Specifications ...
Page 220: ...B 6 Interrupt Request PCI IRQ Device I O Port Address Assignments ...
Page 231: ...D ROMPilot BIOS Error Codes ROMPilot BIOS Error Codes ...
Page 234: ...D 4 ROMPilot BIOS Error Codes ...
Page 235: ...E Connectors Overview External Device Connector Pin Information ...
Page 250: ...10 Glossary ...
Page 256: ...Index 4 ...
Page 257: ...xx ...