4-14 Configuring Your Server
Server
Option
Parameter
Description
Your Setting
System
Management
–
System Management submenu is
displayed.
Console
Redirection
–
Console Redirection submenu is
displayed.
Assert NMI on
PERR
Disabled
[Enabled]
Indicates whether PCI PERR is
supported or not.
Assert NMI on
SERR
Disabled
[Enabled]
Indicates whether PCI SERR is
supported or not.
Post Error Pause
Disabled
[Enabled]
Indicates whether POST is aborted once
at the end of POST if an error occurs
during the execution of POST.
AC LINK
Stay Off
[Last State]
Power On
Indicates the AC LINK function. Shows
the state of the power of the server.
[ ]: Factory-set
IMPORTANT:
To power on the server from the UPS (Uninterruptible
Power Supply), select [Server] - [AC LINK] - [Power On].
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC LINK."
Setting of AC LINK
System status before AC power off
Stay Off
Last State
Power On
Operating
Off
On
On
Aborting (DC power being off also)
Off
Off
On
Forced shutdown
Off
Off
On
* Press the power switch continuously for four seconds or longer. This forcibly turns off the
power.
Summary of Contents for Express5800/120Rg-2
Page 10: ...iv This page is intentionally left blank ...
Page 32: ...1 16 Notes on Using Your Server This page is intentionally left blank ...
Page 192: ...6 24 Installing and Using Utilities This page is intentionally left blank ...
Page 204: ...7 12 Maintenance This page is intentionally left blank ...
Page 298: ...9 58 Upgrading Your Server This page is intentionally left blank ...
Page 300: ...A 2 Specifications This page is intentionally left blank ...
Page 308: ...C 2 IRQ This page is intentionally left blank ...
Page 338: ...F 4 Product Configuration Record Table This page is intentionally left blank ...