2. System BIOS Setup
Express5800/T110j User’s Guide
108
Chapter 3 Setup
2.4
Cases that Require Setting Changes
Specify parameters according to the following table when your system matches "Description". Other than cases
described below, do not change the settings. The list of SETUP parameters and factory settings are described
in
Chapter 2 (1. System BIOS)
in "
Maintenance Guide
".
Category
Description
To be changed
Remark
Basic
Change date and time
Main
System Date
Main
System Time
Configurable on OS
On/Off NumLock on power ON
Boot
Bootup Numlock State
On/Off the function to display
the NEC logo during POST
Boot
Quite Boot
Disabled
By pressing <Esc> key,
prevent the display of the logo.
Optional
board
A RAID controller is installed
Advanced
PCI Subsystem
PCI
Express Slot n I/O ROM
Enabled
n
is PCI slot number of the
RAID controller
When an optional board is
installed besides the RAID
controller, set to
Disabled
for
Option ROM for all PCI
devices except for the boot
device.
Advanced
PCI Subsystem
PCI
Express Slot n I/O ROM
Disabled
n
is PCI slot number of the
RAID controller
Boot
Change the boot order of
devices
Boot
FIXED BOOT ORDER
Priorities
Change the boot priority
Control from HW console
terminal
Advanced
Serial Port Console
Redirection
Change respective
setting.
Set to
Disabled
in
X2APIC
Opt Out
depending on the
installed OS.
Chipset
System Agent (SA)
Configuration
X2APIC Opt Out
Disabled
The following OSs are applicable:
-
Red Hat Enterprise Linux 7
-
Windows Server 2019
-
Windows Server 2016
-
VMware ESXi 6.5
-
VMware ESXi 6.7
For details, see
Installation
Guide
.
Summary of Contents for EXP339
Page 127: ...MEMO...