INKA, IOR, REPO & LINK
IOR
REPO
Configure the unit to transmit a radio
message using the ID code of the
received message when a radio message
is received in position 1…8
Select “Send same” in list box 131…138
IOR
REPO
Configure the unit to transmit a radio
alarm using the ID code of the received
message when a radio message is
received with the
fixed input
ID code
Select “Send same” in list box 139
IOR
REPO
Configure the unit to transmit a radio
alarm using the ID code of the received
message when a radio message is
received that does not have a pre-
programmed ID code
Select “Send same” in list box 140
3.4.2 Alarm Type for Transmitted Alarm
The alarm type in transmitted alarms can be configured individually for each wired input and for each
radio position. By default, the special alarm type
No alarm type
is chosen. This means that the home
care phone NEO will determine the alarm type depending on radio position used in NEO.
If any other alarm type than
No alarm type
is chosen, then the home care will use the alarm type
configured in the INKA, IOR or REPO. Any alarm type in the list can be chosen for transmitted alarms.
Each alarm type has its own meaning, but it is up to the user that configures the unit to make sure that
the correct alarm type is used.
When input 4 is configured as
analog sample
, choose alarm type
measurement data
for input 1. See
section 3.2.2 for a description of
analog sample
mode. Likewise, when input 5 is configured as
analog
sample
, choose alarm type
measurement data
for input 2.
When configuring alarm type for transmitted radio alarms trigged by a received radio message, it is
also possible to choose the alarm type
transparent
. This means that the alarm type of the transmitted
alarm will be the same as the alarm type of the received message.
The alarm type for transmitted alarms when a wired input is trigged is configured in the fields of the
column
alarm type
under the
wired input
tab.
INKA
IOR
Configure alarm type for transmitted alarm
when wired input 1…5 is trigged
Select alarm type from the list in list box
241...245
Technical Handbook for the IOR Family (firmware v20.x), document number NE41 06007-02 v1.0