Input Requirements
A-2
420-Watt Power Supply Requirements
Input Requirements
The following represent the input requirements of the 420-watt power supply:
•
Maximum waveform harmonic distortion shall be less than 5%. The
power supply must operate above frequency with both 100~120/200~240
VRMS input voltage ranges.
•
The power supply must operate over both voltage ranges with an outside
switch.
The table below shows the 420-watt power supply input requirements.
Table A-1. 420-Watt Power Supply Input Requirements
Input
Frequency
Nominal Frequency
Frequency
Variations
50 Hz
60 Hz
47 Hz ~ 53 Hz
57 Hz ~ 63 Hz
Input Voltage
Nominal Voltage
Variation Range
100 ~ 120 VRMS
200 ~ 240 VRMS
90 ~ 132 VRMS
180 ~ 264 VRMS
Input Current
Maximum Input Current
Measuring
Range
8 A
4 A
90 ~ 132 VRMS
180 ~ 264 VRMS
Inrush Current
The power supply inrush current shall be less than the ratings of
its critical components (including the fuse, rectifiers, and the
surge-limiting device) for all conditions of line voltage.
Efficiency
63% minimum (measuring at maximum load, applying nominal
line)
Summary of Contents for S26
Page 1: ...BST0 2140 4700 12 97 NCR S26 Hot Plug Server User Guide Release 3...
Page 11: ...NCR S26 Hot Plug Server User Guide 1 1 Chapter 1 Installation and Documentation Overview...
Page 19: ...NCR S26 Hot Plug Server User Guide 2 1 Chapter 2 Using System Features...
Page 33: ...NCR S26 Hot Plug Server User Guide 3 1 Chapter 3 Adding and Replacing Components...
Page 52: ...Installing Drives 3 20 Adding and Replacing Components Figure 3 10 Securing the Drive...
Page 56: ...Installing Drives 3 24 Adding and Replacing Components...
Page 57: ...NCR S26 Hot Plug Server User Guide 4 1 Chapter 4 Using the BIOS Setup Utility...
Page 91: ...NCR S26 Hot Plug Server User Guide 5 1 Chapter 5 Using the System Utilities...
Page 109: ...NCR S26 Hot Plug Server User Guide A 1 Appendix A 420 Watt Power Supply Requirements...
Page 112: ...Output Requirements A 4 420 Watt Power Supply Requirements...
Page 113: ...NCR S26 Hot Plug Server User Guide B 1 Appendix B Error Messages...
Page 119: ...NCR S26 Hot Plug Server User Guide C 1 Appendix C Sample Configurations...
Page 141: ...NCR S26 Hot Plug Server User Guide D 1 Appendix D Hot Plug Backplane...
Page 161: ...NCR S26 Hot Plug Server User Guide E 1 Appendix E System Support Log...
Page 188: ...Software Records E 28 System Support Log This page intentionally left blank...
Page 219: ...Index NCR S26 Hot Plug Server User Guide Index 3 V Ventilation 2 7...
Page 220: ...Index Index 4 NCR S26 Hot Plug Server User Guide...