1-12 Chapter 1: Product Overview
Definitions of the states involved
Mechanical
Off:
System
is
not
working.
No
AC
power
is
connected
to
the
system.
Operational
parameters
are
not
saved.
System
resets
and
initializes
when
transitioning
to
the
Full
On
State.
Entry:
a)
Remove
power
from
unit.
Exit:
Connect
power
to
unit.
(move
to
Soft
Off
or
Full
On
or
APM
Enabled
)
Soft
Off:
AC
Power
is
connected
to
the
system.
Only
the
5V
standby
and
3.3V
standby
voltages
are
present
within
the
machine.
Entry:
a)
Connect
power
to
unit.
(Assuming
“Status
after
power
fail”
in
BIOS
Setup
is
configured
for
“Off”
after
power
cycle
or
it
is
configured
for
“Previous
Status”
and
the
previous
status
was
off
when
AC
power
was
removed.
b)
Turn
off
unit
via
power
button.
Power
button
can
be
configured
for
either
instant
off
or
for
off
after
being
pressed
for
longer
than
four
seconds.
c)
Unit
turned
off
via
software
control
Exit:
a)
Press
power
button
b)
Wake
On
LAN
(*)
c)
Wake
ON
Ring
(*)
d)
Wake
On
Alarm
(*)
e)
Remove
AC
Note:
Function
has
no
effect
with
any
of
the
following
conditions:
a)
First
time
AC
is
connected
b)
Power
button
delay
is
set
to
4
seconds
into
Soft
Off
state
c)
BIOS
is
not
set
to
enable
these
functions
Summary of Contents for 7446
Page 1: ...NCR RealPOS 30 7446 Release 2 1 User Guide 2 B005 0000 1551 Issue E...
Page 90: ......
Page 98: ...3 8 Chapter 3 Setup...
Page 148: ...A 10 Appendix A Cables...