86 NPE Service Manual
Fault
Possible
Causes
Check method
Flame loss and noise
occurs after ignition
Model
Gas Type
Offset
NPE-150S
NG
-0.04"±0.01"
LP
-0.03"±0.01"
NPE-180A
NPE-180S
NG
-0.04"±0.01"
LP
-0.03"±0.01"
NPE-210A
NPE-210S
NG
-0.04"±0.01"
LP
-0.02"±0.01"
NPE-240A
NPE-240S
NG
-0.04"±0.01"
LP
-0.02"±0.01"
Check the offset values for low fire
Offset value for low fire
Flame Rod
(Electrode)
Replace the electrode or clean the fire detecting electrode.
-
Cause: Due to the properties of the electrode, the oxide film is created due to
long-term exposure to the high temperature; therefore, errors may be caused in
detecting the fires.
-
Check-up: Use sandpaper to clean the fire detecting electrode covered with oxide
film or replace it.