Version 2.21
62 NPE Service Manual
4.11.5 Flame Rod Assembly
Part
Check Point
Function
To ignite gas by repeatedly discharging a high voltage spark to the main burner until gas ignites.
Failure Event
1. Unable to ignite during the ignition process.
2. Produces multiple unsuccessful attempts to ignite.
Effects
1. The unit cannot ignite during the ignition process and “E003” or “E004” error codes will display.
2. Durability of the igniter wears down
Error Code
E003, E004, E012
Diagnostic
Visual inspection: Connection and/or breakage of wires.
Color/Number
of wires
BLACK: 0~10 uA
Bracket
Flame rod
Igniter
Gap distance : 3.5~4.5mm (1/8”)