85
Installation Checklist
Connecting the Power Supply
Yes
No
Is the supplied voltage 110-120V AC?
Is the boiler plugged into a properly grounded outlet?
If you have made a direct power supply connection, have you installed a power switch to facilitate end-user
maintenance?
Have you checked the polarity of the electrical connection?
PCB DIP switch setting (DIP SW 2, set of 8)
Yes
No
Gas type: Is switch #1 set correctly for LP (ON) or NG (OFF)?
If continuous boiler operation is required, is switch #7 in the up (ON) position?
If high temperature venting has been installed (CPVC or polypropylene), is switch #8 in the up (ON) position?
Operating the boiler
Yes
No
Have you shown the owner how to clean the inlet water filter?
Have you given the Installation & Operation Manual and User’s Information Manual to the owner for future reference?
Have you shown the owner how to shut off the gas in case of an emergency?