32 Installing the System Piping
3.6.3 System Application - Zone System with Pumps (Primary/Secondary Piping)
Make-up Water
Additional Zone
Zone #2
Zone #1
Air Separator
Not to exceed 4 pipe Dia or Max. 12"
Pressure
Relief Valve
Expansion Tank
NaviClean
Air Vent
Pressure
reducing valve
Backflow
preventer
Note
●
System application drawings are intended to explain the system piping concept only.
●
Install a NaviClean filter in the system return to remove foreign objects from the system. Foreign objects inside the system may
result in abnormal system operation.
●
Refer to “3.4 Filling the System” on page 28 for make-up water connections and refer to the requirements of your local codes
to ensure compliance.
●
Use a pump with an integral check valve or install a check valve at the pump outlet.
●
Refer to “3.7.3 Wiring Diagram - Zone Pump System” on page 39 for wiring connections.
Summary of Contents for NFC-175
Page 122: ...Memo...
Page 123: ...Memo...