93
Operating the Boiler
11.3.6 Viewing Other System Information
To view the miscellaneous system information, press the Menu
button (
), and then select “6. EMS Data”.
Rotate the Command dial (
) to switch between the information
items. Press the Command dial (
) to select an item and view the
information.
Press the Back button (
) to return to the previous screen or
menu.
Item
Description
1. SH Operation Time
View monthly space heating operation
logs.
2. DHW Operation
Time
View monthly DHW operation logs.
3. Gas Consumption
View monthly gas consumption.
11.3.5 Viewing Error History
To view the error history, press the Menu button (
), and then
select “5. Error History”.
A list of 10 recent errors are displayed on the screen, with the most
recent error displayed at the top of the list.
Rotate the Command dial (
) to switch between the list of errors.
Press the Command dial (
) to select an error to view detailed
information.
Press the Back button (
) to return to the previous screen or
menu.
Note
●
The front panel display flashes in red and the error
icon is displayed (flashing) when a level 1 error is
detected. You can press the Command dial (
) to
enter error display mode. Boiler operation is
maintained during a level 1 error.
●
A level 1 error is automatically cleared when the
problem is resolved.
●
You can press the power button to clear a level1 error.
Then the error is cleared if the problem has been
resolved.